Project ID: 994978 DEA: 09379504 EFIS: 0919000009
QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-5709-
Work Description: CONSTRUCT BUILDING AND PLACE HMA.
Location Description: INYO COUNTY AT INDEPENDENCE AT THE INDEPENDENCE MAINTENANCE STATION AT 665 NORTH EDWARDS STREET
Contractor Name: FEC FUTURE CONTRACTORS AND ENGINEERS INC
Contractor Address: 184 Technology Drive, Irvine, CA 92618
Resident Engineer: George Elzawy Structure Rep.: Derek Armon
DIME Sample ID: 2024-12-17-56
TL Number from the TL Form: 4553
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 12/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/18/2024
The quantity of what the sample constitutes: 250
A brief description of the sample: 4x8 Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: PCC-02
Structure unique identifier:
Structure name: Independence Equipment Canopy
The fabricator/manufacturer/facility name: 7/11
The concrete mix design number: 718416A6
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge Chute of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-12-17-56-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: PCC-02
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
5 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5140 psi
|
|
Maximum load on cylinder 1
|
65080 lb
|
|
Maximum load on cylinder 2
|
63940 lb
|
|
Maximum load on cylinder 3
|
64660 lb
|
|
Compressive strength of cylinder 1
|
5180.0 psi
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Compressive strength of cylinder 2
|
5090.0 psi
|
|
Compressive strength of cylinder 3
|
5140 psi
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|