Print Report | Back to Sample Detail

Sample Record for 2025-01-17-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995202 DEA: 033H6104 EFIS: 0318000019 QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA-80-42.7/49.3
Work Description: RDWY EXC, HMA, JPCP, ALT PIPELINER, STEEL SOLDIER PILE, MOD LTG SYSTEM
Location Description: PLACER COUNTY ABOUT 9.4 MILES NORTH OF COLFAX FROM 0.5 MILE WEST OF MONTE VISTA OVERCROSSING TO 0.3 MILE EAST OF DRUM FOREBAY OVERCROSSING
Contractor Name: DESILVA GATES CONSTRUCTION, LLC
Contractor Address: 11555 Dublin Blvd, Dublin, CA 94568
Resident Engineer: Tad Sampson Structure Rep.: Jimmer Ross

Sample Information

DIME Sample ID: 2025-01-17-7
TL Number from the TL Form:
Sample Submitted By Organization: Rinker Materials
Sample Organization Contact: (916) 381-3910
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/17/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/17/2025
The quantity of what the sample constitutes: Day's Production
A brief description of the sample: 4x8 Concrete Cylinders
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Rinker Materials

Material Information

The concrete mix design number: mix#5
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2-14550
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Conveyor Belt
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2025-01-17-7-1
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (916) 381-3910
This test has been superseded on 01/21/2025. The corrected test ID is: 2025-01-17-7-3
Reason: retested

Test 2 of 6

DIME Test ID: 2025-01-17-7-2
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 01/21/2025
Date Tested: 01/17/2025
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: edgar.benitez@rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 54 F

Test 3 of 6

DIME Test ID: 2025-01-17-7-3
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (916) 381-3910
This test has been superseded on 01/21/2025. The corrected test ID is: 2025-01-17-7-4
Reason: retested

Test 4 of 6

DIME Test ID: 2025-01-17-7-4
Test Method: CTM TEMP1-16: Test Method for Monitoring Precast Concrete Curing Temperature (Curing temperature)
Verified Date: 01/21/2025
Date Tested: 01/17/2025
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: edgar.benitez@rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
The test was superseded from test ID: 2025-01-17-7-3
Test Result Compliance:
Additional Comments When Verified:
Precast Maximum Curing Temperature 137

Test 5 of 6

DIME Test ID: 2025-01-17-7-5
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/29/2025
Date Tested: 01/24/2025
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: edgar.benitez@rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 6190 psi
Maximum load on cylinder 1 79995 lb
Maximum load on cylinder 2 75890 lb
Maximum load on cylinder 3 77575 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 6 of 6

DIME Test ID: 2025-01-17-7-6
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/18/2025
Date Tested: 02/18/2025
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: edgar.benitez@rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 8220 psi
Maximum load on cylinder 1 104865 lb
Maximum load on cylinder 2 104525 lb
Maximum load on cylinder 3 100460 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data