Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044K2404 Cty MRN Rte 1 PM 10.9, 10.8/10.9, 10.90, 6.6/10.9 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Dawit Habteselassie |
Date Reported: |
05/22/2017 |
|
|
Address: |
TL Number: |
|
||
|
City: |
||||
|
Project Name: Construct Solier Pile Wall |
||||
|
Prime Contractor: Drill Tech |
||||
|
Sample Taken Date: |
04/22/2017 |
Mix Design: |
4700P |
|
|
Contractor: Unknown |
Location : |
|||
|
Structure unique identifier: Retaining Wall |
||||
|
Structure name: Retaining Wall |
||||
|
Location of Pour: soldier pile wall |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 6.00 | 28.27 | 197568 | 6988.6 | 1 |
| 2 | 6.01 | 28.37 | 196243 | 6917.3 | 1 |
DIME Test ID: 2017-04-22-1-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6950
Age of specimen: 30 days
Certified By: Mike Mullins
|
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing