Sample Record for 2025-01-15-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994574 DEA: 050C7334 EFIS: 0518000116
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-10.5/13.4
Work Description: CONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location Description: SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 580 West Beach Street, Watsonville, CA 95076
Resident Engineer: Fernando Dos Santos Structure Rep.: Daniel Dait
Sample Information
DIME Sample ID: 2025-01-15-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 01/15/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/21/2025
The quantity of what the sample constitutes: 165
A brief description of the sample: 2'-8" dia. #6 rebar hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1201063498
Hoop Manufacturer Lot Number(s): 1 & 2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #6
Diameter of Hoop: 2'-8"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor Utah
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded
Test Results
Test 1 of 1
DIME Test ID: 2025-01-15-6-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 02/13/2025
Date Tested: 02/13/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
8
|
| Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | | 1 | 1 | 6 | 0.44 | 44260 | 101000 | ok necking | Kleinfelder | | 2 | 1 | 6 | 0.44 | 45000 | 102000 | ok necking | Kleinfelder | | 3 | 1 | 6 | 0.44 | 43960 | 100000 | ok necking | Kleinfelder | | 4 | 1 | 6 | 0.44 | 46190 | 105000 | ok necking | Kleinfelder | | 1 | 2 | 6 | 0.44 | 41570 | 94500 | ok necking | Kleinfelder | | 2 | 2 | 6 | 0.44 | 43470 | 99000 | ok necking | Kleinfelder | | 3 | 2 | 6 | 0.44 | 44200 | 100000 | ok necking | Kleinfelder | | 4 | 2 | 6 | 0.44 | 44180 | 100000 | ok necking | Kleinfelder |
| |
|
UTM
|
NA
|
|
Temperature
|
0000 f
|