Print Report | Back to Sample Detail

Sample Record for 2025-01-15-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994574 DEA: 050C7334 EFIS: 0518000116 QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-10.5/13.4
Work Description: CONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location Description: SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 580 West Beach Street, Watsonville, CA 95076
Resident Engineer: Fernando Dos Santos Structure Rep.: Daniel Dait

Sample Information

DIME Sample ID: 2025-01-15-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Control
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 01/15/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/15/2025
The quantity of what the sample constitutes: 201
A brief description of the sample: 4'-2" dia. #8 rebar hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 1201063511
Hoop Manufacturer Lot Number(s): 1 & 2
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #8
Diameter of Hoop: 4'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: Nucor Utah
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test 1 of 2

DIME Test ID: 2025-01-15-2-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 02/13/2025
Date Tested: 01/21/2025
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11#80.797208091240PassJon Garland
21#80.797204091190PassJon Garland
31#80.797045089180PassJon Garland
41#80.796922087620PassJon Garland
UTM 400KIP
Temperature 62 f

Test 2 of 2

DIME Test ID: 2025-01-15-2-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 02/13/2025
Date Tested: 01/21/2025
Submitted By Organization: Construction Testing Services
Organization Address: 2118 Rheem Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: rring@cts-1.com
Organization Phone: (925) 351-6905
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12#80.797155090570PassJon Garland
22#80.797153090540PassJon Garland
32#80.797189091000PassJon Garland
42#80.797141090390PassJon Garland
UTM 400KIP
Temperature 62 f