Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000578 DEA: 112N1704 EFIS: 1122000283
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-15.72-28.3
Work Description: Bridge Preservation
Location Description: In San Diego at various locations from Landis Street Overcrossing to Sorrento Valley Boulevard Undercrossing
Contractor Name: Myers & Sons Construction
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Alex Balce Structure Rep.: Unknown
DIME Sample ID: 2025-01-11-1
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/11/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/14/2025
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: PSU
From where was the sample collected: Source
Laboratory sample identification: 1601-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2025-01-11-1-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 02/03/2025
Date Tested: 02/03/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target = 4.70% Passed 4.95%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3959.6 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6015.2 g
|
|
Mass of HMA Sample prior to ignition
|
2055.6 g
|
|
Corrected Asphalt Binder Content
|
4.95 %
|
|
Mass Loss
|
118.8 g
|
|
Mass of aggregate remaining after ignition
|
1936.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.83 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2025-01-11-1-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/16/2025
Date Tested: 01/15/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.515 Tested 2.523
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2546.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
9012.7 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.523
|
|
Theoretical maximum density at 25°C (77°F)
|
157 lb/ft^3
|
DIME Test ID: 2025-01-11-1-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Air Voids and tested an Avg of 3.9% Air Voids
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.422
|
|
Bulk Specific Gravity 2
|
2.425
|
|
Bulk Specific Gravity 3
|
2.428
|
|
Average Bulk Specific Gravity
|
2.425
|
DIME Test ID: 2025-01-11-1-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Air Voids and tested an Avg of 3.9% Air Voids
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4 %
|
|
Percent Air Voids 2
|
3.9 %
|
|
Percent Air Voids 3
|
3.8 %
|
|
Average Percent Air Voids
|
3.9 %
|
DIME Test ID: 2025-01-11-1-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 01/24/2025
Date Tested: 01/24/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target WET > 70 and DRY > 100
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
283 psi
|
|
Average Wet Tensile Strength
|
200 psi
|
|
Tensile Strength Ratio
|
0.71
|
DIME Test ID: 2025-01-11-1-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 01/23/2025
Date Tested: 01/22/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm Tested Avg of 1.98 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
0.39 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
0.96 mm
|
|
Average impression at 5000 passes (left/right avg)
|
0.68 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
0.79 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.81 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.3 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
1.15 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.82 mm
|
|
Average impression at 15000 passes (left/right avg)
|
1.98 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2025-01-11-1-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/24/2025
Date Tested: 01/24/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4011.3 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5660.6 g
|
|
Mass of HMA Sample prior to ignition
|
1649.3 g
|
|
Corrected Asphalt Binder Content
|
6.37 %
|
|
Mass Loss
|
105 g
|
|
Mass of aggregate remaining after ignition
|
1544.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|