Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994511 Permit Numbers: 04216RC0290
QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-12-19.97-20.10
Work Description: Extension of curb and sidewalk along the project frontage on hwy 12 to the Calistoga
Location Description:
Contractor Name: Deacon Construction, LLC
Contractor Address: 7745 Greenback Lane Suite 250, Citrus Heights, CA 95610
Resident Engineer: Arvind Sidhu Structure Rep.: Unknown
DIME Sample ID: 2025-01-13-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: Concrete Core
Sample Taken Date: 01/13/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/13/2025
The quantity of what the sample constitutes: 2 concrete cores
A brief description of the sample: 2 concrete cores 4x8
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Intersection between Calistoga Rd in santa rosa
Detail description: 2 Concrete Cores
Structure names: Pavement
Type of material: Concrete core
DIME Test ID: 2025-01-13-8-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 01/14/2025
Date Tested: 01/14/2025
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test: Cylinder 1 - Core #2
Cylinder 2 - Core #3
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
2
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
1 lb
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
4940 psi
|
|
Maximum load on cylinder 1
|
69574 lb
|
|
Maximum load on cylinder 2
|
55747 lb
|
|
Compressive strength of cylinder 1
|
5480.0 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
4390.0 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
Cylinder 1 - Core #2
Cylinder 2 - Core #3
|
|
Correction factor for cylinder 1
|
0.99
|
|
Correction factor for cylinder 2
|
0.99
|
|
Age of specimen
|
169 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|