Project Information

Project ID: 994931 DEA: 120R1704 EFIS: 1218000062 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-1-8.5
Work Description: REPLACE TRAFFIC SIGNALS, INSTALL LIGHTING, AND RECONSTRUCT CURB RAMPS.
Location Description: ORANGE COUNTY IN LAGUNA BEACH AT CRESS STREET
Contractor Name: INTERNATIONAL LINE BUILDERS, INC. DBA ILB ELECTRIC
Contractor Address: 3955 Temescal Canyon Rd, Corona, CA 92883
Resident Engineer: Bibars Kattao Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-12-09-54
TL Number from the TL Form:
Sample Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Sample Organization Contact: 9492798846
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/11/2024
The quantity of what the sample constitutes: 9
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-0502
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertson's

Material Information

The concrete mix design number: 5236125A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: DRY Condition CIDH Piles, Traffic Signals & Lighting
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-12-09-54-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/09/2025
Date Tested: 12/19/2024
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 3.99 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 3.99 in
Cross sectional area of cylinder 1 12.5 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.5 in^2
Compressive strength (to nearest 10 psi) 4350 psi
Maximum load on cylinder 1 56560 lb
Maximum load on cylinder 2 54180 lb
Maximum load on cylinder 3 52840 lb
Compressive strength of cylinder 1 4524.8 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4310.3 psi
Compressive strength of cylinder 3 4227.2 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 10 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2024-12-09-54-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/09/2025
Date Tested: 12/23/2024
Submitted By Organization: CT D12 - Huntington Beach Field Laboratory
Organization Address: 19601 Beach Boulevard,
Organization City: Huntington Beach
Organization State: CA
Organization Zipcode: 92648
Organization Email: frank.mai@dot.ca.gov
Organization Phone: (949) 279-8846
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 3.99 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.5 in^2
Compressive strength (to nearest 10 psi) 4700 psi
Maximum load on cylinder 1 59540 lb
Maximum load on cylinder 2 57760 lb
Maximum load on cylinder 3 59780 lb
Compressive strength of cylinder 1 4736.7 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4595.1 psi
Compressive strength of cylinder 3 4782.4 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours