Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-11-15-53
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 11/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2024
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Slag Cement
From where was the sample collected: Source
Laboratory sample identification: CM245471
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Rizhao Slag
DIME Test ID: 2024-11-15-53-1
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 03/04/2026
Date Tested: 02/14/2025
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: Initial residue and correction factor not available.
Test Result Compliance:
Additional Comments When Verified:
|
Corrected residue, % (Rc)
|
no data0 %
|
|
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325)
|
100 %
|
DIME Test ID: 2024-11-15-53-2
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 03/04/2026
Date Tested: 02/14/2025
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: Raw test data not available.
Test Result Compliance:
Additional Comments When Verified:
Due to test owner's privacy settings, you do not have permission to view this test data.
|
Method Used
|
Test Method A
|
|
Test Time
|
no data0 seconds
|
|
Fineness
|
3880 cm^2/g
|
DIME Test ID: 2024-11-15-53-3
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 03/04/2026
Date Tested: 02/14/2025
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: Raw data not available. Only SpGr and Air content are true values.
Test Result Compliance:
Additional Comments When Verified:
Due to test owner's privacy settings, you do not have permission to view this test data.
|
Specific gravity
|
2.91
|
|
Water Content
|
1
|
|
The amount of flow (In percent)
|
1 %
|
|
The amount of water used (In percent)
|
69.14 %
|
|
Net Weight of Sample
|
1 grams
|
|
Air Content
|
8 %
|
DIME Test ID: 2024-11-15-53-4
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 03/04/2026
Date Tested: 02/14/2025
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Due to test owner's privacy settings, you do not have permission to view this test data.
|
Density of hydraulic cement
|
2.91 g/cm^3
|
DIME Test ID: 2024-11-15-53-5
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/04/2026
Date Tested: 02/14/2025
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Due to test owner's privacy settings, you do not have permission to view this test data.
|
Will control cubes be used per ASTM C311?
|
yes
|
|
Age of specimen
|
7 days
|
|
The amount of flow
|
108 %
|
|
The amount of water used
|
97.9 %
|
|
Compressive strength of 1st specimen
|
3770 psi
|
|
Compressive strength of 2nd specimen
|
3720 psi
|
|
Compressive strength of 3rd specimen
|
3700 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
3730 psi
|
|
Average Compressive strength (to nearest 10 psi) control group
|
3740 psi
|
|
Strength Activity Index of Portland Cement per ASTM C109
|
100 %
|
DIME Test ID: 2024-11-15-53-6
Test Method: ASTM C109-21: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 03/04/2026
Date Tested: 03/07/2025
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Due to test owner's privacy settings, you do not have permission to view this test data.
|
Will control cubes be used per ASTM C311?
|
yes
|
|
Age of specimen
|
28 days
|
|
The amount of flow
|
108 %
|
|
The amount of water used
|
98 %
|
|
Compressive strength of 1st specimen
|
5440 psi
|
|
Compressive strength of 2nd specimen
|
5350 psi
|
|
Compressive strength of 3rd specimen
|
5350 psi
|
|
Average Compressive strength (to nearest 10 psi)
|
5380 psi
|
|
Average Compressive strength (to nearest 10 psi) control group
|
4480 psi
|
|
Strength Activity Index of Portland Cement per ASTM C109
|
120 %
|
DIME Test ID: 2024-11-15-53-7
Test Method: ASTM C114-23-24: Slag Cement Chemical Analysis: ASTM C114 (17.2) & ASTM C989
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
Data has not been verified.