Project Information

Project ID: 1000805 DEA: 061G0904 EFIS: 0623000237 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-41-R28.2
Work Description: Fre 41 Santa Ana Pump Replace. Remove existing pump, install temporary pump, and replace pump and associated appurtenances.
Location Description: Fresno County along Route 41 near PM R28.2 at Pump Plant between Shaw Ave and Santa Ana Ave.
Contractor Name: KOCH & KOCH, INC. PM: Ric Eli
Contractor Address: 13084 John Bauer Avenue, Grass Valley, CA 95945
Resident Engineer: Martin Garcia Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-12-19-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/19/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/20/2024
The quantity of what the sample constitutes: 1CY
A brief description of the sample: Pump Pedestal
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 42-0381W
Structure name: Santa Ana Ave Pump Plant
The fabricator/manufacturer/facility name: Outback Materials

Material Information

The concrete mix design number: 63T1G01C
The truck number from where the sample was collected: 86
The batch plant ticket number from where the sample was collected: 173836
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-12-19-11-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 2200 psi
Maximum load on cylinder 1 27780 lb
Maximum load on cylinder 2 27220 lb
Maximum load on cylinder 3 27990 lb
Compressive strength of cylinder 1 2210.0 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 2165.5 psi
Compressive strength of cylinder 3 2226.7 psi
Type of fracture pattern of cylinder 2 6
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2024-12-19-11-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/30/2025
Date Tested: 01/30/2025
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 2450 psi
Maximum load on cylinder 1 29900 lb
Maximum load on cylinder 2 30610 lb
Maximum load on cylinder 3 31790 lb
Compressive strength of cylinder 1 2378.7 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 2435.2 psi
Compressive strength of cylinder 3 2529 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 42 days
Age of specimen in hours no data0 hours