Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000274 DEA: 041X2804 EFIS: 0424000295
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-84-11.2 or 15.5
Work Description: Repair Slip Out
Location Description: Niles Canyon
Contractor Name: Pacific Coast Drilling Co., Inc. (Aaron Sykes)
Contractor Address: 364 Bellevue Ave., Santa Rosa 95407
Resident Engineer: Eddie Dike Structure Rep.: Jordan Jarosz
DIME Sample ID: 2024-12-16-16
TL Number from the TL Form: C771703
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 12/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/17/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4-inch HMA Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton
DIME Test ID: 2024-12-16-16-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/20/2024
Date Tested: 12/20/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Burn #1
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2901.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4941.4 g
|
|
Mass of HMA Sample prior to ignition
|
2039.6 g
|
|
Corrected Asphalt Binder Content
|
4.79 %
|
|
Mass Loss
|
124.9 g
|
|
Mass of aggregate remaining after ignition
|
1914.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.19 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
482 C
|