Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000368 DEA: 081J4704 EFIS: 0818000055
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R87.9,R91.0
Work Description: PARTIALLY GROUTED RSP, STRUCTURE EXCAVATION AND ROADWAY EXCAVATION.
Location Description: RIVERSIDE COUNTY NEAR CHIRIACO SUMMIT AT THREE STAR DITCH BRIDGE AND AT DETERMINATION DITCH BRIDGE
Contractor Name: GRIFFITH COMPANY
Contractor Address: 3050 BIRCH STREET, BREA, CA 92821
Resident Engineer: Peter Koury Structure Rep.: Unknown
DIME Sample ID: 2024-12-17-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 12/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/18/2024
The quantity of what the sample constitutes: 4 BOXES OF RHMA, 1 QT PG64-16, 1 QT RUBBER BLEND
A brief description of the sample: 3/4" RWMA G SP .3% EVO
From where was the sample collected: Manufacturer
Laboratory sample identification: 0685G-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Desert Hot Springs
DIME Test ID: 2024-12-17-11-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/23/2024
Date Tested: 12/19/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2160.4 g
|
|
Corrected Asphalt Binder Content
|
7.44 %
|
|
Mass Loss
|
161.8 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
-0.09 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|