Print Report | Back to Sample Detail

Sample Record for 2024-06-07-122

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994686 DEA: 051K4604 EFIS: 0518000210 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-46-29.7/32.2
Work Description: COLD PLANE, PLACE HMA, RHMA, CONC PVMT, MODIFY SIGNAL AND LIGHTING.
Location Description: SAN LUIS OBISPO COUNTY IN PASO ROBLES FROM 300 FEET WEST OF ROUTE 101/46 SEPARATION TO 0.1 MILE EAST OF AIRPORT ROAD
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: 800 FARROLL RD, GROVER BEACH, CA 93433
Resident Engineer: Michael Schmidt Structure Rep.: Ray Barajas

Sample Information

DIME Sample ID: 2024-06-07-122
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Paso Robles Field Laboratory
Sample Organization Contact: 1 (209) 610-9363
Type of Sample: Quality Assurance
Type of Material: Concrete Core
Sample Taken Date: 06/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/07/2024
The quantity of what the sample constitutes: 100CY
A brief description of the sample: PCC cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CALPORTLAND

Material Information

Detail description: 28 Day
Structure names: crash cushion pad
Type of material: PCC Concrete

Test Results

Test 1 of 1

DIME Test ID: 2024-06-07-122-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/13/2024
Date Tested: 07/05/2024
Submitted By Organization: CT D05 - Paso Robles Field Laboratory
Organization Address: CA,
Organization City: ,
Organization State: CA
Organization Zipcode: 93422
Organization Email: isaac.larey.chezem@dot.ca.gov
Organization Phone: (805) 234-6493
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4470 psi
Maximum load on cylinder 1 55067 lb
Maximum load on cylinder 2 57553 lb
Maximum load on cylinder 3 55904 lb
Compressive strength of cylinder 1 4380.8 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4578.6 psi
Compressive strength of cylinder 3 4447.4 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours 672 hours