Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-37.4-52.6
Work Description: I-5 NCC SEGMENT 4C
Location Description: I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing
Contractor Name: Flatiron-Skanska-Stacy and Witbeck Joint Venture
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Yong Pak Structure Rep.: Phong Le
DIME Sample ID: 2024-11-07-56
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/05/2024
The quantity of what the sample constitutes: 36 boxes
A brief description of the sample: PSU
From where was the sample collected: Supplier
Laboratory sample identification: 0613-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan CC
DIME Test ID: 2024-11-07-56-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/23/2025
Date Tested: 01/10/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Target = 5.2 Tested 5.56
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4015.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5575.4 g
|
|
Mass of HMA Sample prior to ignition
|
1559.5 g
|
|
Corrected Asphalt Binder Content
|
5.56 %
|
|
Mass Loss
|
99.1 g
|
|
Mass of aggregate remaining after ignition
|
1460.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.79 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-11-07-56-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/16/2024
Date Tested: 12/12/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.478 Tested 2.464
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1532.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8386.2 grams
|
|
Temperature of Water
|
no data0 °F
|
|
Specific Gravity for Sample 1
|
2.464
|
|
Theoretical maximum density at 25°C (77°F)
|
153.4 lb/ft^3
|
DIME Test ID: 2024-11-07-56-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 12/16/2024
Date Tested: 12/12/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0 , +/- 1.5 % Tested 4.2% Avg of 3
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.361
|
|
Bulk Specific Gravity 2
|
2.362
|
|
Bulk Specific Gravity 3
|
2.357
|
|
Average Bulk Specific Gravity
|
2.36
|
DIME Test ID: 2024-11-07-56-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 12/16/2024
Date Tested: 12/12/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested 4.2%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4.2 %
|
|
Percent Air Voids 2
|
4.1 %
|
|
Percent Air Voids 3
|
4.3 %
|
|
Average Percent Air Voids
|
4.2 %
|
DIME Test ID: 2024-11-07-56-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 01/23/2025
Date Tested: 12/19/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target WET> 70 and DRY>100 Tensile> .50
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
211 psi
|
|
Average Wet Tensile Strength
|
117 psi
|
|
Tensile Strength Ratio
|
0.55
|
DIME Test ID: 2024-11-07-56-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 12/16/2024
Date Tested: 12/13/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm Tested 2.01 mm Avg
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
0.94 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
2.04 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.49 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
1.07 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
2.52 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.8 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
1.23 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.79 mm
|
|
Average impression at 15000 passes (left/right avg)
|
2.01 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2024-11-07-56-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/19/2024
Date Tested: 12/17/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP Gradation
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3983.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5633.4 g
|
|
Mass of HMA Sample prior to ignition
|
1649.7 g
|
|
Corrected Asphalt Binder Content
|
7.18 %
|
|
Mass Loss
|
118.4 g
|
|
Mass of aggregate remaining after ignition
|
1531.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-11-07-56-8
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/23/2025
Date Tested: 01/02/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 308 RAP Burn 320819 CC SJR use 7.18% for Blanks
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3983.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5633.4 g
|
|
Mass of HMA Sample prior to ignition
|
1649.7 g
|
|
Corrected Asphalt Binder Content
|
7.18 %
|
|
Mass Loss
|
118.4 g
|
|
Mass of aggregate remaining after ignition
|
1531.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|