Print Report | Back to Sample Detail

Sample Record for 2024-12-04-43

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994328 DEA: 081H0604 EFIS: 0816000130 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-74-34.3/45.1
Work Description: FIBER OPTIC CABLE SYSTEMS, RHMA, HMA, AND MINOR CONCRETE.
Location Description: RIVERSIDE COUNTY IN AND NEAR HEMET FROM WINCHESTER ROAD TO FAIRVIEW AVENUE
Contractor Name: GRIFFITH COMPANY
Contractor Address: Unknown
Resident Engineer: Omar Sanchez Structure Rep.: Arnel Vega

Sample Information

DIME Sample ID: 2024-12-04-43
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 12/04/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/05/2024
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Perris

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2024-12-04-43-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 12/16/2024
Date Tested: 12/10/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 58 C
Softening Point Sample 2 58 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2024-12-04-43-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 12/16/2024
Date Tested: 12/10/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 37 0.1 mm

Test 3 of 3

DIME Test ID: 2024-12-04-43-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 12/16/2024
Date Tested: 12/10/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 4 mm
Final Dial reading (F1) 65 mm
Ball Penetration (P2) 5 mm
Final Dial reading (F2) 66 mm
Ball Penetration (P3) 4 mm
Final Dial reading (F3) 64 mm
Resilience 1 39 %
Resilience 2 39 %
Resilience 3 40 %
Average Resilience 39 %
Minutes Reaction no data