Print Report | Back to Sample Detail

Sample Record for 2024-12-06-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-12-06-15
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 12/06/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/09/2024
The quantity of what the sample constitutes: 3
A brief description of the sample: PT Strand
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden

Material Information

Comments:
Reel/Coil/Pack Number(s): S336919-3, S336928-6, S380748-3
Number of Coils:
Group Number:
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0529624, S0589124, S0586624
Mfg. Lot Number(s): S336919-3, S336928-6, S380748-3
Manufacturer(s): Sumiden

Test Results

Test 1 of 1

DIME Test ID: 2024-12-06-15-1
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 12/18/2024
Date Tested: 12/14/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 9
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0529624S336919-30.600616605856015.821.84Atlas Technical Consultants
S0529624S336919-30.217620005670029.861.6828Atlas Technical Consultants
S0529624S336919-30.217613105545027.261.8396Atlas Technical Consultants
S0589124S336928-60.217602605428025.571.7164Atlas Technical Consultants
S0589124S336928-60.217606605320024.121.8256Atlas Technical Consultants
S0589124S336928-60.217605805384025.351.8368Atlas Technical Consultants
S0586624S380748-30.217604505468027.821.9292Atlas Technical Consultants
S0586624S380748-30.217602705382026.091.8452Atlas Technical Consultants
S0586624S380748-30.217602705317025.171.9124Atlas Technical Consultants
UTM NA
Temperature 0 f