Print Report | Back to Sample Detail

Sample Record for 2024-11-18-45

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995067 DEA: 11430394 EFIS: 1118000115 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-805-23.9/25.1
Work Description: WIDEN FREEWAY, STRUCTURES, CONSTRUCT SIGNS, LANDSCAPE AND ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE NORTH OF ROUTE 805/52 SEPARATION TO 0.3 MILE SOUTH OF NOBEL DRIVE OVERCROSSING
Contractor Name: GRIFFITH COMPANY
Contractor Address: 13400 Sabre Spring Parkway Ste 200, San Diego, CA 92128
Resident Engineer: Tyler Jones Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2024-11-18-45
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 11/18/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/05/2024
The quantity of what the sample constitutes: 3 bags
A brief description of the sample: RPSU Aggs
From where was the sample collected: Source
Laboratory sample identification: 1007-RPSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

Source Identification (SMARA, name of Pit or Job Site): N/A
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 23417005SR MM

Test Results

Test 1 of 11

DIME Test ID: 2024-11-18-45-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 12/06/2024
Date Tested: 12/05/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced and Fine 1 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, fine, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 99 %
Percentage of fractured, fine, 1 faced particles tested 96 %

Test 2 of 11

DIME Test ID: 2024-11-18-45-3
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 12/06/2024
Date Tested: 12/05/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method B
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat and elongated 0 %
Weighted percentage of particles (by number) that were not flat and elongated 0 %

Test 3 of 11

DIME Test ID: 2024-11-18-45-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 12/06/2024
Date Tested: 12/05/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 66

Test 4 of 11

DIME Test ID: 2024-11-18-45-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 12/06/2024
Date Tested: 12/06/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.703
Absorption 0.8 %

Test 5 of 11

DIME Test ID: 2024-11-18-45-5
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 12/06/2024
Date Tested: 12/06/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.505
Bulk specific gravity (SSD Basis) 2.570
Apparent specific gravity 2.679
Absorption 2.6 %

Test 6 of 11

DIME Test ID: 2024-11-18-45-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 12/06/2024
Date Tested: 12/06/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: NA ( No Natural Sand) <10%
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.505
Average uncompacted voids 41.3 %

Test 7 of 11

DIME Test ID: 2024-11-18-45-9
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/06/2024
Date Tested: 12/06/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies - RAP Rice
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1555.6 grams
Mass of container filled with the sample and water for Sample 1 8390.3 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.427
Theoretical maximum density at 25°C (77°F) 151.1 lb/ft^3

Test 8 of 11

DIME Test ID: 2024-11-18-45-7
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 12/17/2024
Date Tested: 12/09/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 4225 grams
Percent loss after 100 revolutions 3 %
Percent loss after 500 revolutions 16 %

Test 9 of 11

DIME Test ID: 2024-11-18-45-10
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 12/17/2024
Date Tested: 12/09/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: RAP
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? Yes
Aggregate correction factor for the 2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1 in. sieve (% passing) no data0 %
Aggregate correction factor for the 3/4 in. sieve (% passing) no data0 %
Aggregate correction factor for the 1/2 in. sieve (% passing) -0.4 %
Aggregate correction factor for the 3/8 in. sieve (% passing) -0.3 %
Aggregate correction factor for the #4 sieve (% passing) -1.9 %
Aggregate correction factor for the #8 sieve (% passing) -2.2 %
Aggregate correction factor for the #16 sieve (% passing) -1.9 %
Aggregate correction factor for the #30 sieve (% passing) -1.5 %
Aggregate correction factor for the #50 sieve (% passing) -0.6 %
Aggregate correction factor for the #100 sieve (% passing) 0.1 %
Aggregate correction factor for the #200 sieve (% passing) 0.6 %
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 99 %
Cumulative percent passing the 3/8 in. sieve 92 %
Cumulative percent passing the #4 sieve 66 %
Cumulative percent passing the #8 sieve 47 %
Cumulative percent passing the #16 sieve 35 %
Cumulative percent passing the #30 sieve 26 %
Cumulative percent passing the #50 sieve 19 %
Cumulative percent passing the #100 sieve 14 %
Cumulative percent passing the #200 sieve 10.1 %

Test 10 of 11

DIME Test ID: 2024-11-18-45-11
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 12/17/2024
Date Tested: 12/09/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 11 of 11

DIME Test ID: 2024-11-18-45-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 12/17/2024
Date Tested: 12/09/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does not comply. Tested twice, failed twice
Test Result Compliance: does not comply
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 83 %
Cumulative percent passing the 3/8 in. sieve 63 %
Cumulative percent passing the #4 sieve 38 %
Cumulative percent passing the #8 sieve 25 %
Cumulative percent passing the #16 sieve 16 %
Cumulative percent passing the #30 sieve 10 %
Cumulative percent passing the #50 sieve 5 %
Cumulative percent passing the #100 sieve 3 %
Cumulative percent passing the #200 sieve 1.6 %