Sample Record for 2024-12-03-16
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994239 DEA: 010H0214 EFIS: 0118000107
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-169-19.0/33.0
Work Description: Cappell Walls
Location Description: HUMBOLDT COUNTY NEAR PECWAN FROM 3.4 MILES WEST OF CAPPELL CREEK BRIDGE TO 0.4 MILE EAST OF WEITCHPEC SCHOOL ROAD (Description of Work: Construct Soldier Pile Wall, Install Drainage, Place HMA (Type A))
Contractor Name: Mercer-Fraser Company
Contractor Address: PO Box 1006, Eureka, CA 95502
Resident Engineer: Efren Banuelos Structure Rep.: Dustin Helliwell
Sample Information
DIME Sample ID: 2024-12-03-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Boyd Road Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/03/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/23/2024
The quantity of what the sample constitutes: 102
A brief description of the sample: Type II/V Cement
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 12-04E0051
Structure name: School Wall
The fabricator/manufacturer/facility name: Mercer Fraser Willow Crk
Material Information
The concrete mix design number: MFWCCL2SLAG
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: WC107156
Concrete batch plant: Willow Creek Mercer Fraser Plant
The fabricator/manufacturer designation for the sample: Batch
A detailed description of where the material sample was collected: Concrete Chute
Where the material sample would have been placed if not sampled: Structural Concrete, Barrier Slab
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 2
DIME Test ID: 2024-12-03-16-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/17/2024
Date Tested: 12/17/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 12/17/24 14 Day Break
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5060 psi
|
|
Maximum load on cylinder 1
|
61860 lb
|
|
Maximum load on cylinder 2
|
65880 lb
|
|
Maximum load on cylinder 3
|
63170 lb
|
|
Type of fracture pattern of cylinder 1
|
4
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
4
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
14 days
|
|
Age of specimen in hours
|
no data0 hours
|
Test 2 of 2
DIME Test ID: 2024-12-03-16-3
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/31/2024
Date Tested: 12/31/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1050 River Ranch Road,
Organization City: Fortuna
Organization State: California
Organization Zipcode: 95540
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 28 Day Break 12/31/24
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Average diameter of cylinder 1
|
4.00 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.00 in
|
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
|
Compressive strength (to nearest 10 psi)
|
6110 psi
|
|
Maximum load on cylinder 1
|
72690 lb
|
|
Maximum load on cylinder 2
|
75810 lb
|
|
Maximum load on cylinder 3
|
82080 lb
|
|
Type of fracture pattern of cylinder 1
|
5
|
|
Type of fracture pattern of cylinder 2
|
5
|
|
Type of fracture pattern of cylinder 3
|
5
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|
|
Age of specimen in hours
|
no data0 hours
|
Tests Assigned to this Sample
| DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
| 2024-12-03-16-1 | CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders | 12/03/2024 | 12/10/2024 | Dustin Helliwell | CT D01 - District 1 Materials Laboratory | 7 Day Break 12/10/24 | Tom Brown |
121580