Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212778 DEA: 023H6504 EFIS: 0218000004
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-5-25.2/38.6
Work Description: HMA, THERMOPLASTIC TRAFFIC STRIPE, COLD PLANE AC PAVEMENT, GUARDRAIL.
Location Description: SISKIYOU COUNTY ABOUT 5.0 MILES NORTH OF WEED FROM NORTH EDGEWOOD OVERHEAD TO 0.2 MILE NORTH OF GRENADA OVERCROSSING
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 17400 CLEAR CREEK RD, REDDING CA 96001
Resident Engineer: Austin Henry Structure Rep.: Alejandro Trochez
DIME Sample ID: 2024-05-16-120
TL Number from the TL Form: 899686
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2024
The quantity of what the sample constitutes: 220 Tons
A brief description of the sample: 12 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79531
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: J F Shea Construction - Fawndale Rock and Asphalt - Redding CA
DIME Test ID: 2024-05-16-120-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/03/2024
Date Tested: 09/26/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=4.53%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3112.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5185.3 g
|
|
Mass of HMA Sample prior to ignition
|
2072.8 g
|
|
Corrected Asphalt Binder Content
|
4.54 %
|
|
Mass Loss
|
106.7 g
|
|
Mass of aggregate remaining after ignition
|
1966.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.47 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-05-16-120-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/03/2024
Date Tested: 05/20/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.565
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7334.2 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2518.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8870.9 grams
|
|
Temperature of Water
|
75 °F
|
|
Specific Gravity for Sample 1
|
2.565
|
|
Theoretical maximum density at 25°C (77°F)
|
2557.6 kg/m^3
|
DIME Test ID: 2024-05-16-120-3
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 12/03/2024
Date Tested: 12/03/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Nf>15000,
SIP>15000
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>15000
|
|
Stripping Inflection Point (Wheel B)
|
>15000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.66 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.06 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.36 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
2 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.33 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.67 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
2.27 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
1.47 mm
|
|
Average impression at 15000 passes (left/right avg)
|
1.87 mm
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|