Print Report | Back to Sample Detail

Sample Record for 2024-05-16-120

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212778 DEA: 023H6504 EFIS: 0218000004 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-5-25.2/38.6
Work Description: HMA, THERMOPLASTIC TRAFFIC STRIPE, COLD PLANE AC PAVEMENT, GUARDRAIL.
Location Description: SISKIYOU COUNTY ABOUT 5.0 MILES NORTH OF WEED FROM NORTH EDGEWOOD OVERHEAD TO 0.2 MILE NORTH OF GRENADA OVERCROSSING
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 17400 CLEAR CREEK RD, REDDING CA 96001
Resident Engineer: Austin Henry Structure Rep.: Alejandro Trochez

Sample Information

DIME Sample ID: 2024-05-16-120
TL Number from the TL Form: 899686
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2024
The quantity of what the sample constitutes: 220 Tons
A brief description of the sample: 12 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28)
From where was the sample collected: Manufacturer
Laboratory sample identification: D79531
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: J F Shea Construction - Fawndale Rock and Asphalt - Redding CA

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 3

DIME Test ID: 2024-05-16-120-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/03/2024
Date Tested: 09/26/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=4.53%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3112.5 g
Mass of the specimen and specimen basket assembly prior to ignition 5185.3 g
Mass of HMA Sample prior to ignition 2072.8 g
Corrected Asphalt Binder Content 4.54 %
Mass Loss 106.7 g
Mass of aggregate remaining after ignition 1966.1 g
Correction Factor (Percent by mass of HMA Specimen) 0.47 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C

Test 2 of 3

DIME Test ID: 2024-05-16-120-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/03/2024
Date Tested: 05/20/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.565
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7334.2 grams
Mass of oven-dry sample in air for Sample 1 2518.6 grams
Mass of container filled with the sample and water for Sample 1 8870.9 grams
Temperature of Water 75 °F
Specific Gravity for Sample 1 2.565
Theoretical maximum density at 25°C (77°F) 2557.6 kg/m^3

Test 3 of 3

DIME Test ID: 2024-05-16-120-3
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 12/03/2024
Date Tested: 12/03/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Nf>15000, SIP>15000
Test Result Compliance: complies
Additional Comments When Verified:
Specimen Preparation Method no data
Test Temperature 122 F
Air Void Content for specimen A-1 no data
Air Void Content for specimen A-2 no data
Air Void Content for specimen B-1 no data
Air Void Content for specimen B-2 no data
Stripping Inflection Point (Wheel A) >15000
Stripping Inflection Point (Wheel B) >15000
Maximum impression at 5000 passes (left wheel) 1.66 mm
Maximum impression at 5000 passes (right wheel) 1.06 mm
Average impression at 5000 passes (left/right avg) 1.36 mm
Maximum impression at 10000 passes (left wheel) 2 mm
Maximum impression at 10000 passes (right wheel) 1.33 mm
Average impression at 10000 passes (left/right avg) 1.67 mm
Maximum impression at 15000 passes (left wheel) 2.27 mm
Maximum impression at 15000 passes (right wheel) 1.47 mm
Average impression at 15000 passes (left/right avg) 1.87 mm
Average impression at 20000 passes (left/right avg) no data
Average impression at 25000 passes (left/right avg) no data