Sample Record for 2024-12-03-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994525 DEA: 031H9904 EFIS: 0317000043
QA Service Level: 1
DIST-CO-RTE-PM: 03-PLA,NEV-80-68.3/69.7,0.0/R2.7
Work Description: RDWY EXC, PLACE HMA & JPCP, SLAB REPLACEMENT & POLYESTER CONC OVERLAY.
Location Description: PLACER AND NEVADA COUNTIES NEAR KINGVALE FROM 0.3 MILE WEST OF TROY UNDERCROSSING TO 0.2 MILE EAST OF SODA SPRINGS OVERCROSSING
Contractor Name: A. TEICHERT & SON INC DBA TEICHERT CONSTRUCTION
Contractor Address: 4401 Duluth Avenue, Rocklin, CA 95765
Resident Engineer: Randie Babbini Structure Rep.: Carl Anderson
Sample Information
DIME Sample ID: 2024-12-03-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Control Sample
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 12/03/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/13/2025
The quantity of what the sample constitutes: 56
A brief description of the sample: 2" Anchor Bolt Assembly
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Madden Bolt
Material Information
Rocap Number(s):
Heat Number(s): 58063275, 20947330, 20947310 32420520
Nut Mfg. Lot Number(s): BVWR BVVW
Washer Mfg. Lot Number(s): 0724-317
Bolt Specification: ASTM F1554 Gr 55
Bolt Length(s): 5'
Nut Specification: ASTM A563
Washer Specification: ASTM 572-50
Finish: bare and partial galv HDG
Diameter/Size: 2"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 15
DIME Test ID: 2024-12-03-1-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Number of Samples
|
no data
|
| Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
| |
|
UTM
|
NA
|
|
Temperature
|
0 f
|
Test 2 of 15
DIME Test ID: 2024-12-03-1-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.6 mils
|
Test 3 of 15
DIME Test ID: 2024-12-03-1-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
6.7 mils
|
Test 4 of 15
DIME Test ID: 2024-12-03-1-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.8 mils
|
Test 5 of 15
DIME Test ID: 2024-12-03-1-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.7 mils
|
Test 6 of 15
DIME Test ID: 2024-12-03-1-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
28.2
|
|
Spacing
|
Ok
|
Test 7 of 15
DIME Test ID: 2024-12-03-1-7
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
28.5
|
|
Spacing
|
Ok
|
Test 8 of 15
DIME Test ID: 2024-12-03-1-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.1
|
|
Spacing
|
Ok
|
Test 9 of 15
DIME Test ID: 2024-12-03-1-9
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/21/2025
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
no data in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.6
|
|
Spacing
|
Ok
|
Test 10 of 15
DIME Test ID: 2024-12-03-1-10
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
2A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
BVWR
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
2 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
28.5
|
|
Spacing
|
Ok
|
Test 11 of 15
DIME Test ID: 2024-12-03-1-11
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
2B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
no data
|
|
Mfg. Lot Number
|
BVWR
|
|
Finish Coating
|
Plain
|
|
Product Markings
|
no data
|
|
Size
|
2 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30.2
|
|
Spacing
|
Ok
|
Test 12 of 15
DIME Test ID: 2024-12-03-1-12
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
2 in
|
|
Bolt Length
|
60 in
|
|
Pitch Diameter
|
1.8742 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 13 of 15
DIME Test ID: 2024-12-03-1-13
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
2 in
|
|
Bolt Length
|
60 in
|
|
Pitch Diameter
|
1.8875 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 14 of 15
DIME Test ID: 2024-12-03-1-14
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
2 in
|
|
Bolt Length
|
60 in
|
|
Measurement Average
|
7.1 mils
|
Test 15 of 15
DIME Test ID: 2024-12-03-1-15
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/21/2025
Date Tested: 01/21/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
58063275
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
Plain and ASTM F2329 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
2 in
|
|
Bolt Length
|
60 in
|
|
Measurement Average
|
6.7 mils
|