Print Report | Back to Sample Detail

Sample Record for 2024-11-01-58

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000521 DEA: 010P2604 EFIS: 0124000213 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-101-59.9
Work Description: Bridge Deck Replacement
Location Description: Long Valley Creek Bridge
Contractor Name: Myers & Sons Construction
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Roozbeh Hadipour Structure Rep.: Behdad Saebi

Sample Information

DIME Sample ID: 2024-11-01-58
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 11/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/26/2024
The quantity of what the sample constitutes: 1290
A brief description of the sample: #5 Lenton Coupler
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Erico

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: CMC
Coupler Manufacturer: Erico
Intermediate Assembler or Fabricator:
Rebar Size: #5
Coupler Model: A2
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): L9952 LA508
Rebar Heat Number(s): 4142917 6052300 4142866 4143016 4141949
Rebar Size 2 :
Coupler Unique ID: ST-17-01

Test Results

Test 1 of 4

DIME Test ID: 2024-11-01-58-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 12/09/2024
Date Tested: 12/06/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1LOT 150.310.00612826091161Atlas Technical ConsultantsMiguel Baltazar
2LOT 150.310002881092935Atlas Technical ConsultantsMiguel Baltazar
3LOT 150.310002719087710Atlas Technical ConsultantsMiguel Baltazar
4LOT 150.310002845091774Atlas Technical ConsultantsMiguel Baltazar
Temperature 000 f
UTM NA
Halo ID 000

Test 2 of 4

DIME Test ID: 2024-11-01-58-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)
Verified Date: 12/09/2024
Date Tested: 12/06/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Necking Test Option Necking Test Option I
Shape of the Sample Straight Sample
Sample 1 Visible Necking? Yes
Sample 1 Location of Fracture? Threads
Sample 2 Visible Necking? Yes
Sample 2 Location of Fracture? Threads
Sample 3 Visible Necking? Yes
Sample 3 Location of Fracture? Threads
Sample 4 Visible Necking? Yes
Sample 4 Location of Fracture? Threads

Test 3 of 4

DIME Test ID: 2024-11-01-58-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 12/09/2024
Date Tested: 12/06/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1LOT 950.310.0072626084710Atlas Technical ConsultantsMiguel Baltazar
2LOT 950.310002892093290Atlas Technical ConsultantsMiguel Baltazar
3LOT 950.310002768089290Atlas Technical ConsultantsMiguel Baltazar
4LOT 950.310001910061613Atlas Technical ConsultantsMiguel Baltazar
Temperature 000 f
UTM NA
Halo ID 000

Test 4 of 4

DIME Test ID: 2024-11-01-58-4
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 12/09/2024
Date Tested: 12/06/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 4
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1LOT 350.310.00212902093613Atlas Technical ConsultantsMiguel Baltazar
2LOT 350.310002945095000Atlas Technical ConsultantsMiguel Baltazar
3LOT 350.310002838091548Atlas Technical ConsultantsMiguel Baltazar
4LOT 350.310002792090065Atlas Technical ConsultantsMiguel Baltazar
Temperature 000 f
UTM NA
Halo ID 000