Project Information

Project ID: 1000216 DEA: 081G6304 EFIS: 0816000043 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-111-47.2/55.3
Work Description: RHMA-G, REPLACE AC SURFACING, AND COLD PLANE AC PVMT.
Location Description: RIVERSIDE COUNTY IN PALM SPRINGS FROM GOLF CLUB DRIVE TO WEST GATEWAY DRIVE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 3800 Monroe St, Indio Ca 92203
Resident Engineer: Francisco Montellano Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-10-30-55
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 10/30/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/21/2024
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite-Desert Hot Springs

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2024-10-30-55-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 12/16/2024
Date Tested: 11/26/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 66 C
Softening Point Sample 2 66 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2024-10-30-55-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 12/16/2024
Date Tested: 11/26/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 30 0.1 mm

Test 3 of 3

DIME Test ID: 2024-10-30-55-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 12/16/2024
Date Tested: 11/26/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) 3 mm
Final Dial reading (F1) 46 mm
Ball Penetration (P2) 3 mm
Final Dial reading (F2) 46 mm
Ball Penetration (P3) 2 mm
Final Dial reading (F3) 47 mm
Resilience 1 57 %
Resilience 2 57 %
Resilience 3 55 %
Average Resilience 56 %
Minutes Reaction no data