Print Report | Back to Sample Detail

Sample Record for 2024-11-14-48

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000283 DEA: 040Y7904 EFIS: 0422000340 QA Service Level: 1
DIST-CO-RTE-PM: 04-SOL-12,37,80,113,505,780-Var
Work Description: PLACE POLYESTER CONCRETE OVERLAY, & REPLACE JOINT SEAL.
Location Description: SOLANO COUNTY AT VARIOUS LOCATIONS
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: 45 Morrison Avenue, Sacramento, CA 95838
Resident Engineer: Asadullah Sarwary Structure Rep.: Aaron Bennett

Sample Information

DIME Sample ID: 2024-11-14-48
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 11/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2024
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000145KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): AZ4K01804
Batch number: AZ4K01804
Mix number: AZ4K01804

Test Results

Test 1 of 6

DIME Test ID: 2024-11-14-48-1
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 12/31/2024
Date Tested: 12/01/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 5
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.482 in
Sample 1 Ultimate strength 3424 psi
Sample 1 Thickness 0.265 in
Sample 1 Area 0.1277 in^2
Sample 1 Ultimate Strength Actual 437.245 lbs
Sample 1 percent elongation 56.08 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.482 in
Sample 2 Thickness 0.267 in
Sample 2 Area 0.1287 in^2
Sample 2 Ultimate strength 3430 psi
Sample 2 Ultimate Strength Actual 441.441 lbs
Sample 2 percent elongation 47.14 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.481 in
Sample 3 Thickness 0.252 in
Sample 3 Area 0.1212 in^2
Sample 3 Ultimate strength 3441 psi
Sample 3 Ultimate Strength Actual 417.049 lbs
Sample 3 percent elongation 49.57 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.481 in
Sample 4 Thickness 0.261 in
Sample 4 Area 0.1255 in^2
Sample 4 Ultimate strength 3397 psi
Sample 4 Ultimate Strength Actual 426.323 lbs
Sample 4 percent elongation 55.96 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.481 in
Sample 5 Thickness 0.256 in
Sample 5 Area 0.1231 in^2
Sample 5 Ultimate strength 3408 psi
Sample 5 Ultimate Strength Actual 419.525 lbs
Sample 5 percent elongation 55.83 %
Sample 5 Time no data0 MM:SS
Ultimate Strength Average 3420 psi
Percent Elongation Average 53 %

Test 2 of 6

DIME Test ID: 2024-11-14-48-2
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 12/31/2024
Date Tested: 11/21/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1312.36 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 656.181 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1368.44 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 684.22 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1629.15 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 814.574 psi

Test 3 of 6

DIME Test ID: 2024-11-14-48-3
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 12/31/2024
Date Tested: 11/20/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 78 f
Tare weight no data
Initial weight 100.024 grams
Weight at 5 minutes 99.929 grams
Weight at 10 minutes 99.817 grams
Weight at 15 minutes 99.705 grams
Weight at 20 minutes 99.601 grams
Weight at 25 minutes 99.49 grams
Weight at 30 minutes 99.378 grams
Final weight 99.38 grams
Total weight loss 0.64 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 34.62 grams/m^2

Test 4 of 6

DIME Test ID: 2024-11-14-48-4
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 92.5

Test 5 of 6

DIME Test ID: 2024-11-14-48-5
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 6 of 6

DIME Test ID: 2024-11-14-48-6
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 45