Print Report | Back to Sample Detail

Sample Record for 2024-11-21-36

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995124 DEA: 060X3004 EFIS: 0618000051 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-33-69.4/71.5
Work Description: REPLACE ROADWAY PAVEMENT.
Location Description: FRESNO COUNTY IN AND NEAR FIREBAUGH FROM MORRIS KYLE DRIVE TO LYON AVENUE
Contractor Name: BAY CITIES PAVING & GRADING, INC.
Contractor Address: 1450 Civic Court, Building B. #400, Concord, CA 94524
Resident Engineer: Din Dadawalla Structure Rep.: Luis Guzman

Sample Information

DIME Sample ID: 2024-11-21-36
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/15/2024
The quantity of what the sample constitutes: 0-750 Tons Produced
A brief description of the sample: 3/4” HMA
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Santa Fe Aggregates Winton

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 3
Sublot number: 16
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-11-21-36-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/26/2024
Date Tested: 11/22/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 2849.1 g
Mass of the specimen and specimen basket assembly prior to ignition 4967.2 g
Mass of HMA Sample prior to ignition 2118.1 g
Corrected Asphalt Binder Content 5.02 %
Mass Loss 116.5 g
Mass of aggregate remaining after ignition 2001.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.34 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C