Sample Record for 2024-11-22-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211605 DEA: 043G4444 EFIS: 0412000044
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-5.9/7.7
Work Description: SFOBB WEST SPAN MAIN CABLE WRAP. Repair main cable and replace suspender ropes, and tower access doors.
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS FROM 0.1 MILE NORTH OF SAN FRANCISCO ANCHORAGE TO 0.1 MILE SOUTH OF YERBA BUENA ANCHORAGE
Contractor Name: American Bridge Company (Wade Barie)
Contractor Address: 1000 American Bridge Way, Coraopolis, PA 15108
Resident Engineer: Daniel Guzman Structure Rep.: Sergio Gomez
Sample Information
DIME Sample ID: 2024-11-22-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Vallejo Field Laboratory
Sample Organization Contact: 9166394315
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 11/22/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/22/2024
The quantity of what the sample constitutes: 12
A brief description of the sample: 3/4"-10x1-3/4"
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: XKT Engineering
Material Information
Rocap Number(s): W000187845R
Heat Number(s): 1000226199 8000028785 123646
Nut Mfg. Lot Number(s): W000163299
Washer Mfg. Lot Number(s): E3506
Bolt Specification: A325
Bolt Length(s): 1.75"
Nut Specification: A563
Washer Specification: F436
Finish: Hot dipped
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: W000187845
Rocap Test Requirement(s):
Lubricant Requirements(s):
Washer Inner Diameter(s):
Test Results
Test 1 of 96
DIME Test ID: 2024-11-22-1-1
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6886 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 2 of 96
DIME Test ID: 2024-11-22-1-2
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6862 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 3 of 96
DIME Test ID: 2024-11-22-1-3
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6905 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 4 of 96
DIME Test ID: 2024-11-22-1-4
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6921 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 5 of 96
DIME Test ID: 2024-11-22-1-5
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6911 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 6 of 96
DIME Test ID: 2024-11-22-1-6
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6879 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 7 of 96
DIME Test ID: 2024-11-22-1-7
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6988 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 8 of 96
DIME Test ID: 2024-11-22-1-8
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6887 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 9 of 96
DIME Test ID: 2024-11-22-1-9
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6890 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 10 of 96
DIME Test ID: 2024-11-22-1-10
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6907 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 11 of 96
DIME Test ID: 2024-11-22-1-11
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6993 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 12 of 96
DIME Test ID: 2024-11-22-1-12
Test Method: ASME B1.2-83r17: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Pitch Diameter
|
0.6964 in
|
|
Pitch Diameter 2nd
|
no data in
|
Test 13 of 96
DIME Test ID: 2024-11-22-1-13
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
3.1 mils
|
Test 14 of 96
DIME Test ID: 2024-11-22-1-14
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
2.8 mils
|
Test 15 of 96
DIME Test ID: 2024-11-22-1-15
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
3 mils
|
Test 16 of 96
DIME Test ID: 2024-11-22-1-16
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
3.4 mils
|
Test 17 of 96
DIME Test ID: 2024-11-22-1-17
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
2.5 mils
|
Test 18 of 96
DIME Test ID: 2024-11-22-1-18
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
2.3 mils
|
Test 19 of 96
DIME Test ID: 2024-11-22-1-19
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
4.5 mils
|
Test 20 of 96
DIME Test ID: 2024-11-22-1-20
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
2.6 mils
|
Test 21 of 96
DIME Test ID: 2024-11-22-1-21
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
2.7 mils
|
Test 22 of 96
DIME Test ID: 2024-11-22-1-22
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
2.2 mils
|
Test 23 of 96
DIME Test ID: 2024-11-22-1-23
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
3.2 mils
|
Test 24 of 96
DIME Test ID: 2024-11-22-1-24
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Measurement Average
|
3.1 mils
|
Test 25 of 96
DIME Test ID: 2024-11-22-1-25
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.1
|
|
Spacing
|
Ok
|
Test 26 of 96
DIME Test ID: 2024-11-22-1-26
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
26.2
|
|
Spacing
|
Ok
|
Test 27 of 96
DIME Test ID: 2024-11-22-1-27
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
28.2
|
|
Spacing
|
Ok
|
Test 28 of 96
DIME Test ID: 2024-11-22-1-28
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
27.2
|
|
Spacing
|
Ok
|
Test 29 of 96
DIME Test ID: 2024-11-22-1-29
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30
|
|
Spacing
|
Ok
|
Test 30 of 96
DIME Test ID: 2024-11-22-1-30
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
27.9
|
|
Spacing
|
Ok
|
Test 31 of 96
DIME Test ID: 2024-11-22-1-31
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
26.8
|
|
Spacing
|
Ok
|
Test 32 of 96
DIME Test ID: 2024-11-22-1-32
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
26.9
|
|
Spacing
|
Ok
|
Test 33 of 96
DIME Test ID: 2024-11-22-1-33
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.1
|
|
Spacing
|
Ok
|
Test 34 of 96
DIME Test ID: 2024-11-22-1-34
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.8
|
|
Spacing
|
Ok
|
Test 35 of 96
DIME Test ID: 2024-11-22-1-35
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.5
|
|
Spacing
|
Ok
|
Test 36 of 96
DIME Test ID: 2024-11-22-1-36
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/09/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
1000226199
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
1.75 in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
27.2
|
|
Spacing
|
Ok
|
Test 37 of 96
DIME Test ID: 2024-11-22-1-37
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 38 of 96
DIME Test ID: 2024-11-22-1-38
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 39 of 96
DIME Test ID: 2024-11-22-1-39
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 40 of 96
DIME Test ID: 2024-11-22-1-40
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 41 of 96
DIME Test ID: 2024-11-22-1-41
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 42 of 96
DIME Test ID: 2024-11-22-1-42
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 43 of 96
DIME Test ID: 2024-11-22-1-43
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 44 of 96
DIME Test ID: 2024-11-22-1-44
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 45 of 96
DIME Test ID: 2024-11-22-1-45
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 46 of 96
DIME Test ID: 2024-11-22-1-46
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 47 of 96
DIME Test ID: 2024-11-22-1-47
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 48 of 96
DIME Test ID: 2024-11-22-1-48
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Gage Type
|
Pass
|
Test 49 of 96
DIME Test ID: 2024-11-22-1-49
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.9 mils
|
Test 50 of 96
DIME Test ID: 2024-11-22-1-50
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.2 mils
|
Test 51 of 96
DIME Test ID: 2024-11-22-1-51
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.5 mils
|
Test 52 of 96
DIME Test ID: 2024-11-22-1-52
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.6 mils
|
Test 53 of 96
DIME Test ID: 2024-11-22-1-53
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.8 mils
|
Test 54 of 96
DIME Test ID: 2024-11-22-1-54
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.1 mils
|
Test 55 of 96
DIME Test ID: 2024-11-22-1-55
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.4 mils
|
Test 56 of 96
DIME Test ID: 2024-11-22-1-56
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.5 mils
|
Test 57 of 96
DIME Test ID: 2024-11-22-1-57
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.9 mils
|
Test 58 of 96
DIME Test ID: 2024-11-22-1-58
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.2 mils
|
Test 59 of 96
DIME Test ID: 2024-11-22-1-59
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.1 mils
|
Test 60 of 96
DIME Test ID: 2024-11-22-1-60
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3 mils
|
Test 61 of 96
DIME Test ID: 2024-11-22-1-61
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30.8
|
|
Spacing
|
Ok
|
Test 62 of 96
DIME Test ID: 2024-11-22-1-62
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30.7
|
|
Spacing
|
Ok
|
Test 63 of 96
DIME Test ID: 2024-11-22-1-63
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30.6
|
|
Spacing
|
Ok
|
Test 64 of 96
DIME Test ID: 2024-11-22-1-64
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30.8
|
|
Spacing
|
Ok
|
Test 65 of 96
DIME Test ID: 2024-11-22-1-65
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
28.7
|
|
Spacing
|
Ok
|
Test 66 of 96
DIME Test ID: 2024-11-22-1-66
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.7
|
|
Spacing
|
Ok
|
Test 67 of 96
DIME Test ID: 2024-11-22-1-67
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.4
|
|
Spacing
|
Ok
|
Test 68 of 96
DIME Test ID: 2024-11-22-1-68
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.2
|
|
Spacing
|
Ok
|
Test 69 of 96
DIME Test ID: 2024-11-22-1-69
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
31.5
|
|
Spacing
|
Ok
|
Test 70 of 96
DIME Test ID: 2024-11-22-1-70
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
29.2
|
|
Spacing
|
Ok
|
Test 71 of 96
DIME Test ID: 2024-11-22-1-71
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
31.3
|
|
Spacing
|
Ok
|
Test 72 of 96
DIME Test ID: 2024-11-22-1-72
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
8000028785
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
30.2
|
|
Spacing
|
Ok
|
Test 73 of 96
DIME Test ID: 2024-11-22-1-73
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3 mils
|
Test 74 of 96
DIME Test ID: 2024-11-22-1-74
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.7 mils
|
Test 75 of 96
DIME Test ID: 2024-11-22-1-75
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.3 mils
|
Test 76 of 96
DIME Test ID: 2024-11-22-1-76
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.3 mils
|
Test 77 of 96
DIME Test ID: 2024-11-22-1-77
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.4 mils
|
Test 78 of 96
DIME Test ID: 2024-11-22-1-78
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3 mils
|
Test 79 of 96
DIME Test ID: 2024-11-22-1-79
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.3 mils
|
Test 80 of 96
DIME Test ID: 2024-11-22-1-80
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.6 mils
|
Test 81 of 96
DIME Test ID: 2024-11-22-1-81
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
4.5 mils
|
Test 82 of 96
DIME Test ID: 2024-11-22-1-82
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
3.6 mils
|
Test 83 of 96
DIME Test ID: 2024-11-22-1-83
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.4 mils
|
Test 84 of 96
DIME Test ID: 2024-11-22-1-84
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Measurement Average
|
2.7 mils
|
Test 85 of 96
DIME Test ID: 2024-11-22-1-85
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1A
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.2
|
|
Spacing
|
Ok
|
Test 86 of 96
DIME Test ID: 2024-11-22-1-86
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1B
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
40.4
|
|
Spacing
|
Ok
|
Test 87 of 96
DIME Test ID: 2024-11-22-1-87
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1C
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41
|
|
Spacing
|
Ok
|
Test 88 of 96
DIME Test ID: 2024-11-22-1-88
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1D
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
40.4
|
|
Spacing
|
Ok
|
Test 89 of 96
DIME Test ID: 2024-11-22-1-89
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1E
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.4
|
|
Spacing
|
Ok
|
Test 90 of 96
DIME Test ID: 2024-11-22-1-90
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1F
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.3
|
|
Spacing
|
Ok
|
Test 91 of 96
DIME Test ID: 2024-11-22-1-91
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1G
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.3
|
|
Spacing
|
Ok
|
Test 92 of 96
DIME Test ID: 2024-11-22-1-92
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1H
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
43
|
|
Spacing
|
Ok
|
Test 93 of 96
DIME Test ID: 2024-11-22-1-93
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1I
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.8
|
|
Spacing
|
Ok
|
Test 94 of 96
DIME Test ID: 2024-11-22-1-94
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1J
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41
|
|
Spacing
|
Ok
|
Test 95 of 96
DIME Test ID: 2024-11-22-1-95
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1K
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
39.4
|
|
Spacing
|
Ok
|
Test 96 of 96
DIME Test ID: 2024-11-22-1-96
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/10/2025
Date Tested: 01/08/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Atlas Technical Consultants
Test Result Compliance:
Additional Comments When Verified:
|
Sample No.
|
1L
|
|
Rocap Number
|
no data
|
|
Heat Number(s)
|
123646
|
|
Mfg. Lot Number
|
no data
|
|
Finish Coating
|
ASTM A153 - Hot Dip
|
|
Product Markings
|
no data
|
|
Size
|
0.75 in
|
|
Bolt Length
|
no data in
|
|
Hardness Reading Scale
|
C Scale
|
|
Hardness Reading Average
|
41.3
|
|
Spacing
|
Ok
|