Print Report | Back to Sample Detail

Sample Record for 2024-11-21-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215425 DEA: 06360244 EFIS: 0613000005 QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-99-30.6/35.2
Work Description: Widen Freeway & Bridge Construction (Concrete Bridge)
Location Description:
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVE, SYLMAR, CA, 91342
Resident Engineer: Javier Huerta Structure Rep.: Ramandeep Guraya

Sample Information

DIME Sample ID: 2024-11-21-12
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 974-1304
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/21/2024
The quantity of what the sample constitutes: L8SL80
A brief description of the sample: 3/4 HMA-A PG70-10
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name: NB TUL 99 N of Ave 264 Tagus
The fabricator/manufacturer/facility name: Martin Mariatta

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 8
Sublot number: 80
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-11-21-12-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/21/2024
Date Tested: 11/21/2024
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 W Roosevelt Ave,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: paul.klinker@dot.ca.gov
Organization Phone: (559) 974-1304
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2061.7 g
Corrected Asphalt Binder Content 4.48 %
Mass Loss 107.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.15 %
Moisture Content no data0 %
Temperature Compensation Factor 0.6 %
Test Temperature 538 C