Sample Record for 2024-11-17-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 995193 DEA: 07356604 EFIS: 0719000026
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-R10.2/20.2
Work Description: LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
Contractor Name: MYERS & SONS CONSTRUCTION, LLC
Contractor Address: 45 Morrison Ave, Sacramento, CA 95838
Resident Engineer: Jerome Arabe Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2024-11-17-4
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/20/2024
The quantity of what the sample constitutes: 10 cubic yards
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-3566
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A
Material Information
The concrete mix design number: VCTS675
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 2
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2024-11-17-4-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 11/20/2024
Date Tested: 11/20/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
3
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Fracture occurred at a capped section
|
No
|
Is a beam dimensional correction factor used?
|
No
|
Age of specimen
|
3 days
|
Modulus of rupture
|
690 psi
|
Modulus of rupture 2
|
690 psi
|
Modulus of rupture average
|
690 psi
|
Modulus of rupture 3
|
680 psi
|