Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994319 DEA: 023J7104 EFIS: 0222000076
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-89-8.7/12.9
Work Description: PLACE HOT MIX ASPHALT (TYPE A) AND REPLACE AC SURFACING.
Location Description: PLUMAS COUNTY NEAR CRESCENT MILLS FROM ROUTE 70 TO 0.7 MILE SOUTH OF DIXIE CANYON ROAD
Contractor Name: Dig It Construction
Contractor Address: 803 Lorraine Dr, P.O. Box 494, Chester, CA 96020
Resident Engineer: Mike Zdenek Structure Rep.: Unknown
DIME Sample ID: 2024-11-06-44
TL Number from the TL Form: 848921
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 11/06/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/07/2024
The quantity of what the sample constitutes: 1 Bag Coldfeed
A brief description of the sample: 3/8-inch Coldfeed
From where was the sample collected: Manufacturer
Laboratory sample identification: D79769A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dig It Construction - Sierra Cascade Aggregate and Asphalt Products - Chester, CA
Source Identification (SMARA, name of Pit or Job Site): 91-32-0002
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2024-11-06-44-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 11/18/2024
Date Tested: 11/12/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
What type of gradation is being tested?
|
HMA Gradation
|
|
Cumulative percent passing the 2 in. sieve
|
no data
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
95 %
|
|
Cumulative percent passing the #4 sieve
|
39 %
|
|
Cumulative percent passing the #8 sieve
|
20 %
|
|
Cumulative percent passing the #16 sieve
|
13 %
|
|
Cumulative percent passing the #30 sieve
|
9 %
|
|
Cumulative percent passing the #50 sieve
|
7 %
|
|
Cumulative percent passing the #100 sieve
|
5 %
|
|
Cumulative percent passing the #200 sieve
|
3.8 %
|