Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000299 DEA: 042Y4904 EFIS: 0423000121
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC-242,680-Var
Work Description: INDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC PVMT & PLACE HMA (TYPE A).
Location Description: CONTRA COSTA COUNTY AT VARIOUS LOCATIONS
Contractor Name: FBD VANGUARD CONSTRUCTION INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-10-30-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/30/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/04/2024
The quantity of what the sample constitutes: 2 Boxes of 1/2"HMA-Type A Mix & 3 Cores
A brief description of the sample: 1/2"HMA-Type A Mix
From where was the sample collected: Supplier
Laboratory sample identification: Con_24_906
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Pleasanton Drier drum Plant
DIME Test ID: 2024-10-30-47-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/19/2024
Date Tested: 11/04/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Specific Gravity for Sample 1
|
2.535
|
|
Theoretical maximum density at 25°C (77°F)
|
2528 kg/m^3
|
DIME Test ID: 2024-10-30-47-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 11/19/2024
Date Tested: 11/05/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Granite Pleasanton drier drum Plant
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Percent Air Voids
|
92.6 %
|
|
Percent Air Voids 2
|
90.6 %
|
|
Percent Air Voids 3
|
90 %
|
|
Average Percent Air Voids
|
91.1 %
|
|
Average Core Density
|
2.3 %
|
DIME Test ID: 2024-10-30-47-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 11/19/2024
Date Tested: 11/05/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.347
|
|
Bulk Specific Gravity 2
|
2.298
|
|
Bulk Specific Gravity 3
|
2.282
|
|
Average Bulk Specific Gravity
|
2.309
|