Sample Record for 2024-10-31-59
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 1000078 DEA: 051P2804 EFIS: 0522000016
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR,-1-17.02/17.02
Work Description: REPLACE SEPARATION BRIDGE GIRDER.
Location Description: SANTA CRUZ COUNTY IN SANTA CRUZ AT ROUTE 1 NORTHBOUND/17 SEPARATION
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: 2900 Bristol Street, Suite D204, Costa Mesa, CA 92626
Resident Engineer: Ian Nguyen Structure Rep.: Stephen Pozzo
Sample Information
DIME Sample ID: 2024-10-31-59
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Sacramento
Sample Organization Contact: (916) 308-3701
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 10/31/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/31/2024
The quantity of what the sample constitutes: 8
A brief description of the sample: #9 HRC 150 T-Heads
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Headed Reinforcement Corp, Fountain Valley, CA
Material Information
Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 4137349
Head Manufacturer Lot Number(s): 1
Rebar Size: #9
Headed Bar Model Name: HRC 150 THeads
Size of Head: Full Size - 9x
Head Connection Type: Friction Weld
Head Shape: Circular
Rebar Manufacturer: CMC Steel Arizona
Head Manufacturer: HRC Fountain Valley
Head Fabricator: HRC Fountain Valley
Material Standard Code: ASTM A615
Headed Bar Unique ID: 9FW-17-04
Test Results
Test 1 of 1
DIME Test ID: 2024-10-31-59-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 11/14/2024
Date Tested: 11/14/2024
Submitted By Organization: Kleinfelder, Incorporated - Sacramento
Organization Address: 9969 Horn Road,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95827
Organization Email: jslinkard@kleinfelder.com
Organization Phone: (916) 308-3701
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Number of Headed Bar Samples
|
4
|
| Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By | | 1 | 1 | 100280 | 100000 | na | MK | | 1 | 1 | 99680 | 99500 | na | MK | | 1 | 1 | 100090 | 100000 | na | MK | | 1 | 1 | 85490 | 85500 | na | MK |
| |
|
Temperature
|
72 f
|
|
UTM
|
NA
|