Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995240 DEA: 060X3804 EFIS: 0618000060
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-166-0.0/10.2
Work Description: COLD PLANE, PLACE HMA AND CONCRETE PAVEMENT, MODIFY DRAINAGE SYSTEM.
Location Description: KERN COUNTY IN AND NEAR MARICOPA FROM SOUTH JUNCTION ROUTE 33 TO 2.3 MILES WEST OF SAN EMIGDIO CREEK BRIDGE
Contractor Name: Griffith Company
Contractor Address: 1128 Carrier Parkway, Bakersfield ,CA 93308
Resident Engineer: Joy Denny Structure Rep.: Travis Landis
DIME Sample ID: 2024-09-30-90
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 09/30/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/01/2024
The quantity of what the sample constitutes: JPCP
A brief description of the sample: A set of 6 JPCP Cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: HOLIDAY ROCK
The concrete mix design number: 3F5FH001
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 14
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-09-30-90-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/12/2024
Date Tested: 11/12/2024
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test: these results are out of compliance because the initial curing temperature was out of range
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
|
Average diameter of cylinder 1
|
3.99 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
3.99 in
|
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
12.5 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5300 psi
|
|
Maximum load on cylinder 1
|
67460 lb
|
|
Maximum load on cylinder 2
|
67860 lb
|
|
Maximum load on cylinder 3
|
63630 lb
|
|
Compressive strength of cylinder 1
|
5396.8 psi
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Compressive strength of cylinder 2
|
5398.6 psi
|
|
Compressive strength of cylinder 3
|
5090.4 psi
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
4
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
43 days
|
|
Age of specimen in hours
|
no data0 hours
|