Sample Record for 2024-11-01-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995242 DEA: 060Y1304 EFIS: 0619000010 QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-33-40.4/59.3
Work Description: COLD PLANE, PLACE HMA AND RHMA-G, AND REPLACE CULVERTS.
Location Description: KERN COUNTY ABOUT 8 MILES NORTH OF MCKITTRICK FROM CYMRIC WASH BRIDGE TO 0.8 MILE SOUTH OF ROUTE 46
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: P.O. Box 5127,, Bakersfield, CA 93388-5127
Resident Engineer: Jake Garcia Structure Rep.: Albert Heredia

Sample Information

DIME Sample ID: 2024-11-01-28
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 11/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/02/2024
The quantity of what the sample constitutes: supported slab
A brief description of the sample: PCC
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Golden empire Wasco

Material Information

The concrete mix design number: NCT109013
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 208163081
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: BACK OF THE TRUCK
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-11-01-28-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/08/2024
Date Tested: 11/08/2024
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 3470 psi
Maximum load on cylinder 1 43770 lb
Maximum load on cylinder 2 43560 lb
Maximum load on cylinder 3 44120 lb
Compressive strength of cylinder 1 3482.1 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3432.6 psi
Compressive strength of cylinder 3 3493.3 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2024-11-01-28-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/15/2024
Date Tested: 11/15/2024
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 4250 psi
Maximum load on cylinder 1 52370 lb
Maximum load on cylinder 2 53890 lb
Maximum load on cylinder 3 54140 lb
Compressive strength of cylinder 1 4166.3 psi
Type of fracture pattern of cylinder 1 4
Compressive strength of cylinder 2 4287.2 psi
Compressive strength of cylinder 3 4286.6 psi
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 14 days
Age of specimen in hours no data0 hours