| Number of Samples | 1 |
| What is the unit of measurement for theoretical density? | SI Units |
| Mass Determination | Air |
| Method Performed | Mechanical Agitation - Method A |
| Mass of container filled with water 1 | 7335.6 grams |
| Mass of oven-dry sample in air for Sample 1 | 2502.9 grams |
| Mass of container filled with the sample and water for Sample 1 | 8835.1 grams |
| Temperature of Water | 77 °F |
| Specific Gravity for Sample 1 | 2.494 |
| Theoretical maximum density at 25°C (77°F) | 2487 kg/m^3 |
| Bulk Specific Gravity | 2.286 |
| Bulk Specific Gravity 2 | 2.236 |
| Bulk Specific Gravity 3 | 2.274 |
| Average Bulk Specific Gravity | 2.265 |
| Percent Air Voids | 8.3 % |
| Percent Air Voids 2 | 10.3 % |
| Percent Air Voids 3 | 8.8 % |
| Average Percent Air Voids | 9.1 % |
| Average Core Density | 90.9 % |
| Bulk Specific Gravity | 2.255 |
| Bulk Specific Gravity 2 | 2.28 |
| Bulk Specific Gravity 3 | 2.29 |
| Average Bulk Specific Gravity | 2.275 |
| Percent Air Voids | 9.6 % |
| Percent Air Voids 2 | 8.6 % |
| Percent Air Voids 3 | 8.2 % |
| Average Percent Air Voids | 8.8 % |
| Average Core Density | 91.2 % |
| What temperature unit is used? | Celsius |
| Test procedure used? | Method A |
| Mass of the specimen basket assembly | 3547.1 g |
| Mass of the specimen and specimen basket assembly prior to ignition | 5574.8 g |
| Mass of HMA Sample prior to ignition | 2027.7 g |
| Corrected Asphalt Binder Content | 4.94 % |
| Mass Loss | 126.2 g |
| Mass of aggregate remaining after ignition | 1901.5 g |
| Correction Factor (Percent by mass of HMA Specimen) | 1.19 % |
| Moisture Content | no data0 % |
| Temperature Compensation Factor | 0.09 % |
| Test Temperature | 482 C |
| What temperature unit is used? | Celsius |
| Test procedure used? | Method A |
| Mass of the specimen basket assembly | 2871.1 g |
| Mass of the specimen and specimen basket assembly prior to ignition | 4892 g |
| Mass of HMA Sample prior to ignition | 2020.9 g |
| Corrected Asphalt Binder Content | 4.78 % |
| Mass Loss | 123.7 g |
| Mass of aggregate remaining after ignition | 1897.2 g |
| Correction Factor (Percent by mass of HMA Specimen) | 1.19 % |
| Moisture Content | no data0 % |
| Temperature Compensation Factor | 0.15 % |
| Test Temperature | 482 C |