Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-10-11-80
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2024
The quantity of what the sample constitutes: 24 BOXES RWMA
A brief description of the sample: 1/2" RWMA-G
From where was the sample collected: Source
Laboratory sample identification: 1202-JMF
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
DIME Test ID: 2024-10-11-80-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/14/2024
Date Tested: 11/13/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 7.50% Tested 7.70%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4018.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6058.1 g
|
|
Mass of HMA Sample prior to ignition
|
2039.3 g
|
|
Corrected Asphalt Binder Content
|
7.7 %
|
|
Mass Loss
|
172.8 g
|
|
Mass of aggregate remaining after ignition
|
1866.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.77 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-10-11-80-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/12/2024
Date Tested: 11/06/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
no data
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1535.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8378.3 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.426
|
|
Theoretical maximum density at 25°C (77°F)
|
2419 kg/m^3
|
DIME Test ID: 2024-10-11-80-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 11/13/2024
Date Tested: 11/13/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does not Comply
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.282
|
|
Bulk Specific Gravity 2
|
2.28
|
|
Bulk Specific Gravity 3
|
2.282
|
|
Average Bulk Specific Gravity
|
2.281
|
DIME Test ID: 2024-10-11-80-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 11/13/2024
Date Tested: 11/13/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Does not Comply
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Percent Air Voids
|
5.9 %
|
|
Percent Air Voids 2
|
6 %
|
|
Percent Air Voids 3
|
5.9 %
|
|
Average Percent Air Voids
|
5.9 %
|
DIME Test ID: 2024-10-11-80-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 11/13/2024
Date Tested: 11/13/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
105 psi
|
|
Average Wet Tensile Strength
|
72 psi
|
|
Tensile Strength Ratio
|
0.69
|
DIME Test ID: 2024-10-11-80-7
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 11/13/2024
Date Tested: 11/13/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
122 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>20000
|
|
Stripping Inflection Point (Wheel B)
|
>20000
|
|
Maximum impression at 5000 passes (left wheel)
|
4.24 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.9 mm
|
|
Average impression at 5000 passes (left/right avg)
|
3.07 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
6.06 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
2.12 mm
|
|
Average impression at 10000 passes (left/right avg)
|
4.09 mm
|
|
Maximum impression at 15000 passes (left wheel)
|
7.78 mm
|
|
Maximum impression at 15000 passes (right wheel)
|
2.44 mm
|
|
Average impression at 15000 passes (left/right avg)
|
5.11 mm
|
|
Maximum impression at 20000 passes (left wheel)
|
9.46 mm
|
|
Maximum impression at 20000 passes (right wheel)
|
2.66 mm
|
|
Average impression at 20000 passes (left/right avg)
|
6.06 mm
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|