Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994378 DEA: 040K6304 EFIS: 0416000111
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-29-16.4/19.0
Work Description: BRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING.
Location Description: NAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG
Contractor Name: GORDON N. BALL, INC.
Contractor Address: 333 Camile Avenue, Alamo, CA 94507
Resident Engineer: Danilo Patenia Structure Rep.: Unknown
DIME Sample ID: 2024-10-31-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Production Start-Up
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 10/31/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/01/2024
The quantity of what the sample constitutes: 2 Bags of Rap
A brief description of the sample: RAP 25%RAP
From where was the sample collected: Supplier
Laboratory sample identification: Con_24_897
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Vallejo Drier Drum Plant
DIME Test ID: 2024-10-31-25-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/12/2024
Date Tested: 11/01/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Vulcan Vallejo drier Drum Plant
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1973.4 g
|
|
Corrected Asphalt Binder Content
|
6.57 %
|
|
Mass Loss
|
132.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.15 %
|
|
Test Temperature
|
482 C
|
DIME Test ID: 2024-10-31-25-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/12/2024
Date Tested: 11/01/2024
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test: Vulcan Vallejo Drier Drum Plant
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1975.8 g
|
|
Corrected Asphalt Binder Content
|
6.5 %
|
|
Mass Loss
|
131.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.15 %
|
|
Test Temperature
|
482 C
|