Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000284 DEA: 041Y5004 EFIS: 0422000498
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-280-R2.7/R4.2L
Work Description: PLACE POLYESTER CONCRETE OVERLAY, AND REPLACE JOINT SEAL.
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS FROM MONTEREY BOULEVARD ON-RAMP OVERCROSSING TO ROUTE 280/101 SEPARATION
Contractor Name: MCCUEN CONSTRUCTION, INC.
Contractor Address: 1537 Canal Road, Sparks, NV 89434
Resident Engineer: Marcus Washington Structure Rep.: Unknown
DIME Sample ID: 2024-10-23-65
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 10/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/31/2024
The quantity of what the sample constitutes: 10 Tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000143KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-10-23-65-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-10-23-65-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Density Units
|
pounds/gallons
|
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2024-10-23-65-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 06/18/2025
Date Tested: 06/11/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.51 in
|
|
Sample 1 Ultimate strength
|
2519.1 psi
|
|
Sample 1 Thickness
|
0.256 in
|
|
Sample 1 Area
|
0.1306 in^2
|
|
Sample 1 Ultimate Strength Actual
|
329 lbs
|
|
Sample 1 percent elongation
|
50 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.503 in
|
|
Sample 2 Thickness
|
0.237 in
|
|
Sample 2 Area
|
0.1192 in^2
|
|
Sample 2 Ultimate strength
|
2508.4 psi
|
|
Sample 2 Ultimate Strength Actual
|
299 lbs
|
|
Sample 2 percent elongation
|
51 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.504 in
|
|
Sample 3 Thickness
|
0.231 in
|
|
Sample 3 Area
|
0.1164 in^2
|
|
Sample 3 Ultimate strength
|
2474.2 psi
|
|
Sample 3 Ultimate Strength Actual
|
288 lbs
|
|
Sample 3 percent elongation
|
50 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.505 in
|
|
Sample 4 Thickness
|
0.228 in
|
|
Sample 4 Area
|
0.1151 in^2
|
|
Sample 4 Ultimate strength
|
2536.9 psi
|
|
Sample 4 Ultimate Strength Actual
|
292 lbs
|
|
Sample 4 percent elongation
|
54 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.505 in
|
|
Sample 5 Thickness
|
0.231 in
|
|
Sample 5 Area
|
0.1167 in^2
|
|
Sample 5 Ultimate strength
|
2493.6 psi
|
|
Sample 5 Ultimate Strength Actual
|
291 lbs
|
|
Sample 5 percent elongation
|
53 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.509 in
|
|
Sample 6 Thickness
|
0.233 in
|
|
Sample 6 Area
|
0.1186 in^2
|
|
Sample 6 Ultimate strength
|
2512.6 psi
|
|
Sample 6 Ultimate Strength Actual
|
298 lbs
|
|
Sample 6 percent elongation
|
53 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
2507 psi
|
|
Percent Elongation Average
|
52 %
|
DIME Test ID: 2024-10-23-65-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Mean of two volatile content determination
|
45
|
DIME Test ID: 2024-10-23-65-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 06/18/2025
Date Tested: 06/18/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test: Accepted supplier's result.
Test Result Compliance: complies
Additional Comments When Verified:
|
Curing history for Sample 1
|
24hr
|
|
Maximum applied load (P) for Sample 1
|
1420 lb
|
|
Span length for Sample 1
|
9 in
|
|
Break location for Sample 1
|
bond
|
|
Specimen defects/notes for Sample 1
|
no data
|
|
Surface type for Sample 1
|
SSD
|
|
Modulus of rupture (R) for Sample 1
|
710 psi
|
|
Curing history for Sample 2
|
24hr
|
|
Maximum applied load (P) for Sample 2
|
1414 lb
|
|
Span length for Sample 2
|
9 in
|
|
Break location for Sample 2
|
bond
|
|
Specimen defects/notes for Sample 2
|
no data
|
|
Surface type for Sample 2
|
SSD
|
|
Modulus of rupture (R) for Sample 2
|
707 psi
|
|
Curing history for Sample 3
|
24hr
|
|
Maximum applied load (P) for Sample 3
|
1236 lb
|
|
Span length for Sample 3
|
9 in
|
|
Break location for Sample 3
|
bond
|
|
Specimen defects/notes for Sample 3
|
no data
|
|
Surface type for Sample 3
|
SSD
|
|
Modulus of rupture (R) for Sample 3
|
618 psi
|
DIME Test ID: 2024-10-23-65-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 06/18/2025
Date Tested: 06/17/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
|
Diameter of lid
|
154.06 mm
|
|
Room Temperature
|
74 f
|
|
Tare weight
|
no data
|
|
Initial weight
|
100.24 grams
|
|
Weight at 5 minutes
|
100.07 grams
|
|
Weight at 10 minutes
|
99.89 grams
|
|
Weight at 15 minutes
|
99.72 grams
|
|
Weight at 20 minutes
|
99.55 grams
|
|
Weight at 25 minutes
|
99.25 grams
|
|
Weight at 30 minutes
|
99.12 grams
|
|
Final weight
|
99.12 grams
|
|
Total weight loss
|
1.12 grams
|
|
Calculated radius of gallon can lid in cm
|
7.703 cm
|
|
Lid Factor
|
53.645 m^2
|
|
Volatile emission
|
60.082 grams/m^2
|