Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215741 DEA: 01366004 EFIS: 0100000127
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-101-80.0/84.0
Work Description: Indianola Cutoff UC
Location Description: HUMBOLDT COUNTY NEAR EUREKA FROM EUREKA SLOUGH BRIDGE TO BAYSIDE CUTOFF
Contractor Name: Granite Construction Company
Contractor Address: 1324 S. State Street, Ukiah, CA 95482
Resident Engineer: Brenda Howell Structure Rep.: Jarred Burrows
DIME Sample ID: 2024-10-25-24
TL Number from the TL Form:
Sample Submitted By Organization: Kleinfelder, Incorporated - Sacramento
Sample Organization Contact: (916) 308-3701
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 10/25/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/25/2024
The quantity of what the sample constitutes: 5 Lots of 150 Hoops
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: Eureka Slough
The fabricator/manufacturer/facility name: Conco Reinforcing
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 4142970
Hoop Manufacturer Lot Number(s): H105
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: #5
Diameter of Hoop: 1'-6.5"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: CMC Arizona
Welding Company: Conco Reinforcing
Coating Standards: Uncoated
Weld Type: Flash Welded
DIME Test ID: 2024-10-25-24-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 11/01/2024
Date Tested: 11/01/2024
Submitted By Organization: Kleinfelder, Incorporated - Sacramento
Organization Address: 9969 Horn Road,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95827
Organization Email: jslinkard@kleinfelder.com
Organization Phone: (916) 308-3701
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
4
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 1 | H105 | 5 | 0.31 | 30110 | 97000 | na | ML | 2 | H105 | 5 | 0.31 | 29580 | 95500 | na | ML | 3 | H105 | 5 | 0.31 | 29090 | 94000 | na | ML | 4 | H105 | 5 | 0.31 | 30150 | 97500 | na | ML |
| |
UTM
|
NA
|
Temperature
|
72 f
|