Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000018 DEA: 042Q7604 EFIS: 0419000046
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-238,680-0.7/0.8,M0.1
Work Description: RECTANGULAR RAPID FLASHING BEACON SYSTEMS, HMA, CURB RAMP AND SW.
Location Description: ALAMEDA COUNTY IN FREMONT ON ROUTE 680 AT OFF-RAMP TO SCOTT CREEK ROAD AND ON ROUTE 238 AT MISSION BRIDGE COURT
Contractor Name: GHILOTTI BROS, INC.
Contractor Address: 525 Jacoby Street, San Rafael, CA 94901
Resident Engineer: Reza Kamkar Structure Rep.: Unknown
DIME Sample ID: 2024-10-25-21
TL Number from the TL Form: C772355
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/25/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/28/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 3/4"HMA w/25% RAP
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton
DIME Test ID: 2024-10-25-21-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/01/2024
Date Tested: 10/31/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Burn #1
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2896.1 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4916.7 g
|
|
Mass of HMA Sample prior to ignition
|
2020.6 g
|
|
Corrected Asphalt Binder Content
|
4.95 %
|
|
Mass Loss
|
127.9 g
|
|
Mass of aggregate remaining after ignition
|
1892.7 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
1.23 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.15 %
|
|
Test Temperature
|
482 C
|