Print Report | Back to Sample Detail

Sample Record for 2024-08-09-118

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995176 DEA: 051H3104 EFIS: 0516000060 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-154-R5.7/R6.2
Work Description: CONSTRUCT ROUNDABOUT, CURB RAMPS, RUMBLE STRIP AND LIGHTING SYSTEM.
Location Description: SANTA BARBARA COUNTY NEAR SANTA YNEZ FROM 0.3 MILE EAST OF EDISON STREET/BASELINE AVENUE TO 0.2 MILE WEST OF EDISON STREET/BASELINE AVENUE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Joseph Person Structure Rep.: Cliff (Clifford) Replogle

Sample Information

DIME Sample ID: 2024-08-09-118
TL Number from the TL Form:
Sample Submitted By Organization: Precon Products - Simi Valley
Sample Organization Contact: (805) 297-5145
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/09/2024
The quantity of what the sample constitutes: 9 concrete cylinders
A brief description of the sample: Mix 23-SE-10125
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pre-Con Products

Material Information

The concrete mix design number: 23-SE-10125
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 301761
Concrete batch plant: Builders Ready Mix
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Sampled for Delivery Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 7

DIME Test ID: 2024-08-09-118-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 10/30/2024
Date Tested: 08/09/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 89 F

Test 2 of 7

DIME Test ID: 2024-08-09-118-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/30/2024
Date Tested: 08/09/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 6.5 inch

Test 3 of 7

DIME Test ID: 2024-08-09-118-3
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 10/30/2024
Date Tested: 08/09/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Air content 1.3 %

Test 4 of 7

DIME Test ID: 2024-08-09-118-4
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/30/2024
Date Tested: 08/12/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.56 in^2
Cross sectional area of cylinder 2 12.56 in^2
Cross sectional area of cylinder 3 12.56 in^2
Compressive strength (to nearest 10 psi) 3810 psi
Maximum load on cylinder 1 44390 lb
Maximum load on cylinder 2 51120 lb
Maximum load on cylinder 3 48170 lb
Type of fracture pattern of cylinder 1 5
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 3 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test 5 of 7

DIME Test ID: 2024-08-09-118-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/30/2024
Date Tested: 08/15/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.56 in^2
Cross sectional area of cylinder 2 12.56 in^2
Cross sectional area of cylinder 3 12.56 in^2
Compressive strength (to nearest 10 psi) 5030 psi
Maximum load on cylinder 1 63100 lb
Maximum load on cylinder 2 63620 lb
Maximum load on cylinder 3 62920 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 6 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test 6 of 7

DIME Test ID: 2024-08-09-118-6
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/30/2024
Date Tested: 09/16/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Apparent mass of submerged cylinder 1 9 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.56 in^2
Cross sectional area of cylinder 2 12.56 in^2
Cross sectional area of cylinder 3 12.56 in^2
Compressive strength (to nearest 10 psi) 5380 psi
Maximum load on cylinder 1 67810 lb
Maximum load on cylinder 2 67750 lb
Maximum load on cylinder 3 62120 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data

Test 7 of 7

DIME Test ID: 2024-08-09-118-7
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 10/30/2024
Date Tested: 08/09/2024
Submitted By Organization: Precon Products - Simi Valley
Organization Address: 240 West Los Angeles Avenue,
Organization City: Simi Valley
Organization State: CA
Organization Zipcode: 93065
Organization Email: Maximus@preconproducts.com
Organization Phone: 8052975145
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample 5000 psi
Volume of the measure 0.5 ft^3
Density of concrete 150.4 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data