Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000187 DEA: 112N1674 EFIS: 1122000280
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-86-R34.8/64.1
Work Description: POLYESTER CONCRETE OVERLAY, APPLY METHACRYLATE,& JOINT SEALS.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM TRIFOLIUM CANAL BRIDGE (58-0017) TO GODETIA DITCH BRIDGE (58-0067)
Contractor Name: TRUESDELL CORPORATION OF CALIFORNIA, INC.
Contractor Address: 1310 W 23RD ST, TEMPE AZ 85282
Resident Engineer: Guillermo Sillas Structure Rep.: Unknown
DIME Sample ID: 2024-10-22-66
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 10/22/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/25/2024
The quantity of what the sample constitutes: 34 Totes
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000142KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-10-22-66-1
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 12/30/2024
Date Tested: 11/06/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.486 in
|
|
Sample 1 Ultimate strength
|
3051 psi
|
|
Sample 1 Thickness
|
0.254 in
|
|
Sample 1 Area
|
0.1234 in^2
|
|
Sample 1 Ultimate Strength Actual
|
376.493 lbs
|
|
Sample 1 percent elongation
|
70.4 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.484 in
|
|
Sample 2 Thickness
|
0.261 in
|
|
Sample 2 Area
|
0.1263 in^2
|
|
Sample 2 Ultimate strength
|
2986 psi
|
|
Sample 2 Ultimate Strength Actual
|
377.132 lbs
|
|
Sample 2 percent elongation
|
55.8 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.485 in
|
|
Sample 3 Thickness
|
0.262 in
|
|
Sample 3 Area
|
0.1271 in^2
|
|
Sample 3 Ultimate strength
|
2991 psi
|
|
Sample 3 Ultimate Strength Actual
|
380.156 lbs
|
|
Sample 3 percent elongation
|
66.7 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.484 in
|
|
Sample 4 Thickness
|
0.262 in
|
|
Sample 4 Area
|
0.1268 in^2
|
|
Sample 4 Ultimate strength
|
3308 psi
|
|
Sample 4 Ultimate Strength Actual
|
419.454 lbs
|
|
Sample 4 percent elongation
|
76 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.485 in
|
|
Sample 5 Thickness
|
0.255 in
|
|
Sample 5 Area
|
0.1237 in^2
|
|
Sample 5 Ultimate strength
|
3021 psi
|
|
Sample 5 Ultimate Strength Actual
|
373.698 lbs
|
|
Sample 5 percent elongation
|
50 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.484 in
|
|
Sample 6 Thickness
|
0.257 in
|
|
Sample 6 Area
|
0.1244 in^2
|
|
Sample 6 Ultimate strength
|
3168 psi
|
|
Sample 6 Ultimate Strength Actual
|
394.099 lbs
|
|
Sample 6 percent elongation
|
71.1 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
3088 psi
|
|
Percent Elongation Average
|
65 %
|
DIME Test ID: 2024-10-22-66-2
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 12/30/2024
Date Tested: 12/30/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Result
Test Result Compliance: complies
Additional Comments When Verified:
|
Curing history for Sample 1
|
24hr
|
|
Maximum applied load (P) for Sample 1
|
1153.11 lb
|
|
Span length for Sample 1
|
9 in
|
|
Break location for Sample 1
|
bond
|
|
Specimen defects/notes for Sample 1
|
no data
|
|
Surface type for Sample 1
|
SSD
|
|
Modulus of rupture (R) for Sample 1
|
576.554 psi
|
|
Curing history for Sample 2
|
24hr
|
|
Maximum applied load (P) for Sample 2
|
1499.06 lb
|
|
Span length for Sample 2
|
9 in
|
|
Break location for Sample 2
|
bond
|
|
Specimen defects/notes for Sample 2
|
no data
|
|
Surface type for Sample 2
|
SSD
|
|
Modulus of rupture (R) for Sample 2
|
749.53 psi
|
|
Curing history for Sample 3
|
24hr
|
|
Maximum applied load (P) for Sample 3
|
1369.09 lb
|
|
Span length for Sample 3
|
9 in
|
|
Break location for Sample 3
|
bond
|
|
Specimen defects/notes for Sample 3
|
no data
|
|
Surface type for Sample 3
|
SSD
|
|
Modulus of rupture (R) for Sample 3
|
684.544 psi
|
DIME Test ID: 2024-10-22-66-3
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 12/30/2024
Date Tested: 10/29/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
|
Diameter of lid
|
153.9 mm
|
|
Room Temperature
|
78 f
|
|
Tare weight
|
no data
|
|
Initial weight
|
100.026 grams
|
|
Weight at 5 minutes
|
99.91 grams
|
|
Weight at 10 minutes
|
99.826 grams
|
|
Weight at 15 minutes
|
99.72 grams
|
|
Weight at 20 minutes
|
99.631 grams
|
|
Weight at 25 minutes
|
99.547 grams
|
|
Weight at 30 minutes
|
99.462 grams
|
|
Final weight
|
99.46 grams
|
|
Total weight loss
|
0.57 grams
|
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
|
Lid Factor
|
53.757 m^2
|
|
Volatile emission
|
30.426 grams/m^2
|
DIME Test ID: 2024-10-22-66-4
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 05/02/2025
Date Tested: 04/28/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-10-22-66-5
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 05/02/2025
Date Tested: 04/28/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Density Units
|
pounds/gallons
|
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2024-10-22-66-6
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 05/02/2025
Date Tested: 04/28/2025
Submitted By Organization: Future Labs, LLC
Organization Address: 124 Lone Wolf Drive,
Organization City: Madison
Organization State: MS
Organization Zipcode: 39110
Organization Email: alexh@futurelabsllc.com
Organization Phone:
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Mean of two volatile content determination
|
45
|