Print Report | Back to Sample Detail

Sample Record for 2024-10-01-108

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000037 DEA: 120U2404 EFIS: 1223000058 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-91-R9.8/R18.9
Work Description: REPLACE CONCRETE SLABS, EXISTING LOOP DETECTORS AND TRAFFIC STRIPING.
Location Description: ORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE
Contractor Name: PETERSON-CHASE GENERAL ENGINEERING CONSTRUCTION, INC.
Contractor Address: 16351 CONSTRUCTION CIRCLE WES, IRVINE, CA 92606
Resident Engineer: Theodore Pham Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-10-01-108
TL Number from the TL Form:
Sample Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Sample Organization Contact: (909) 793-7602
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/02/2024
The quantity of what the sample constitutes: 10 cy
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pro-Cast Products

Material Information

The concrete mix design number: RRM14062
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Ready Mix Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 3

DIME Test ID: 2024-10-01-108-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: bmalott@procastproducts.com
Organization Phone: (909) 809-2429
Data has not been verified.

Test 2 of 3

DIME Test ID: 2024-10-01-108-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 10/29/2024
Date Tested: 10/01/2024
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: bmalott@procastproducts.com
Organization Phone: (909) 809-2429
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 8.5 inch

Test 3 of 3

DIME Test ID: 2024-10-01-108-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/29/2024
Date Tested: 10/29/2024
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street,
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: bmalott@procastproducts.com
Organization Phone: (909) 809-2429
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1 no data0 lb
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 7770 psi
Maximum load on cylinder 1 219440 lb
Maximum load on cylinder 2 219770 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data0 hours
Serial number of delivery ticket, if available no data