Project Information
Project ID: 994332 DEA: 11430444 EFIS: 1118000204
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-8,78-Var
Work Description: REHABILITATE BRIDGES, CONCRETE BARRIERS, TERMINAL SYSTEMS, ELECTRICAL.
Location Description: IMPERIAL COUNTY AT VARIOUS LOCATIONS
Contractor Name: J. FRANCIS COMPANY
Contractor Address: 16197 Krameria Ave, Riverside, CA 92504
Resident Engineer: Karl Hartline Structure Rep.: Karl Hartline
Sample Information
DIME Sample ID: 2024-10-17-44
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/21/2024
The quantity of what the sample constitutes: 8 cylinders
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 8812-C
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gibson Shaefer
Material Information
The concrete mix design number: 22044
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Job Site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 4
DIME Test ID: 2024-10-17-44-1
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/24/2024
Date Tested: 10/24/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 7 days, 4426 psi
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
2
|
|
Average Compressive Strength (to nearest 10)
|
4426 lb/in^2
|
|
Cylinder Age
|
7 days
|
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 2 of 4
DIME Test ID: 2024-10-17-44-2
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/29/2024
Date Tested: 10/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 10 days
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
2
|
|
Average Compressive Strength (to nearest 10)
|
4780 lb/in^2
|
|
Cylinder Age
|
10 days
|
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 3 of 4
DIME Test ID: 2024-10-17-44-3
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 11/14/2024
Date Tested: 11/14/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 28 days
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
2
|
|
Average Compressive Strength (to nearest 10)
|
4970 lb/in^2
|
|
Cylinder Age
|
28 days
|
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|
Test 4 of 4
DIME Test ID: 2024-10-17-44-4
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/19/2024
Date Tested: 12/11/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 42 days
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens
|
2
|
|
Average Compressive Strength (to nearest 10)
|
5420 lb/in^2
|
|
Cylinder Age
|
42 days
|
|
Break Description of Cylinder 1 (if not 'cone')
|
no data
|
|
Break Description of Cylinder 2 (if not 'cone')
|
no data
|