Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000231 DEA: 081N6504 EFIS: 0823000029
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-62-38.5/48.5
Work Description: RHMA-G, PARTIAL DEPTH RECYCLING, AND SHOULDER BACKING.
Location Description: SAN BERNARDINO COUNTY NEAR TWENTYNINE PALMS FROM GOPHER GROVE LANE TO GOLD CROWN ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: Unknown
Resident Engineer: Francisco Montellano Structure Rep.: Unknown
DIME Sample ID: 2024-10-15-52
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/24/2024
The quantity of what the sample constitutes: 8 boxes of rhma
A brief description of the sample: 1/2" RHMA-G-SP .5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0574G-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Desert Hot Springs
DIME Test ID: 2024-10-15-52-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/25/2024
Date Tested: 10/25/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1649.7 g
|
|
Corrected Asphalt Binder Content
|
7.66 %
|
|
Mass Loss
|
130.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.01 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.13 %
|
|
Test Temperature
|
538 C
|