Print Report | Back to Sample Detail

Sample Record for 2024-10-19-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-37.4-52.6
Work Description: I-5 NCC SEGMENT 4C
Location Description: I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing
Contractor Name: Flatiron-Skanska-Stacy and Witbeck Joint Venture
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Yong Pak Structure Rep.: Phong Le

Sample Information

DIME Sample ID: 2024-10-19-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/19/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/21/2024
The quantity of what the sample constitutes: 16 boxes
A brief description of the sample: RPSU
From where was the sample collected: Supplier
Laboratory sample identification: 0610-RPSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan CC

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 220817 CC SJR
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 5

DIME Test ID: 2024-10-19-2-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/24/2024
Date Tested: 10/22/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 5.00% Tested 5.05%
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4009.3 g
Mass of the specimen and specimen basket assembly prior to ignition 6058.6 g
Mass of HMA Sample prior to ignition 2049.3 g
Corrected Asphalt Binder Content 5.05 %
Mass Loss 115.5 g
Mass of aggregate remaining after ignition 1933.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.59 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C

Test 2 of 5

DIME Test ID: 2024-10-19-2-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/24/2024
Date Tested: 10/22/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.502 Tested 2 times 1) 2.469 2) 2.473 used 2.473 for calcs
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7475.6 grams
Mass of oven-dry sample in air for Sample 1 2551.7 grams
Mass of container filled with the sample and water for Sample 1 8995.6 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.473
Theoretical maximum density at 25°C (77°F) 153.9 lb/ft^3

Test 3 of 5

DIME Test ID: 2024-10-19-2-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 10/24/2024
Date Tested: 10/22/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested and Avg of 3.6%
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity 2.382
Bulk Specific Gravity 2 2.383
Bulk Specific Gravity 3 2.384
Average Bulk Specific Gravity 2.383

Test 4 of 5

DIME Test ID: 2024-10-19-2-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 10/24/2024
Date Tested: 10/22/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested an Avg of 3.6%
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.7 %
Percent Air Voids 2 3.6 %
Percent Air Voids 3 3.6 %
Average Percent Air Voids 3.6 %

Test 5 of 5

DIME Test ID: 2024-10-19-2-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/24/2024
Date Tested: 10/24/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: 3 RAP Burns. Save material for RAP T30
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3982.6 g
Mass of the specimen and specimen basket assembly prior to ignition 5639.2 g
Mass of HMA Sample prior to ignition 1656.6 g
Corrected Asphalt Binder Content 6.63 %
Mass Loss 109.8 g
Mass of aggregate remaining after ignition 1546.8 g
Correction Factor (Percent by mass of HMA Specimen) no data0 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C