Print Report | Back to Sample Detail

Sample Record for 2024-10-21-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994673 DEA: 033F0704 EFIS: 0312000054 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-51-2.0/3.5
Work Description: American River Bridge Rehabilitation
Location Description:
Contractor Name: American River Constructors
Contractor Address: 4001 Bradshaw Road, Sacramento, CA 95827
Resident Engineer: John Ruzic Structure Rep.: Pha Tran

Sample Information

DIME Sample ID: 2024-10-21-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 10/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/25/2024
The quantity of what the sample constitutes: Four (4) Threaded Bars
A brief description of the sample: Two (2) 1-3/8" Threaded Bar, four (4) 1-3/8" Nuts, and four (4) washers
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering San Diego

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size:
Nut Specification for Threaded Bar: ASTM A29
System Manufacturer: Williams Form Engineering San Diego
Epoxy Coating Color: NA
Threaded Bar Application: Soil Nail
Coating Standards: Uncoated
Bar Heat Number(s): 58052325/04
Nut Heat Number(s): 20762050
Bar Lot Number: 04
Nut Lot Number: 36G9D
Coupler Heat Number(s):
Coupler Grade:

Test Results

Test 1 of 1

DIME Test ID: 2024-10-21-2-2
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 02/03/2025
Date Tested: 02/03/2025
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 3
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
10580523251.58166900130300700Atlas
20580523251.58164500145200700Atlas
30580523251.581595001330009320Atlas
Temperature 0 f
UTM NA