Project Information

Project ID: 994744 DEA: 072XG504 EFIS: 0723000149 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-66.3/67.3
Work Description:
Location Description:
Contractor Name: Powell Constructors Inc
Contractor Address: Unknown
Resident Engineer: Ridwan Salman Structure Rep.: Torch Rivera

Sample Information

DIME Sample ID: 2024-10-02-101
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 10/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/02/2024
The quantity of what the sample constitutes: 20cy
A brief description of the sample: SB 5 Lane #3 Sta 3509+30 to Sta 3513+06
From where was the sample collected: Job Site
Laboratory sample identification: 24-3075
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Short Load Concrete

Material Information

The concrete mix design number: CTS-30-EHI
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Job site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-10-02-101-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/16/2024
Date Tested: 10/16/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 4210 psi
Maximum load on cylinder 1 121278 lb
Maximum load on cylinder 2 118201 lb
Compressive strength of cylinder 1 4261.3 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4166.4 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 5 days
Age of specimen in hours no data0 hours