Project ID: 994378 DEA: 040K6304 EFIS: 0416000111
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-29-16.4/19.0
Work Description: BRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING.
Location Description: NAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG
Contractor Name: GORDON N. BALL, INC.
Contractor Address: 333 Camile Avenue, Alamo, CA 94507
Resident Engineer: Danilo Patenia Structure Rep.: Unknown
DIME Sample ID: 2024-09-27-70
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Fairfield Construction Field Office 59-545
Sample Organization Contact: 510-714-7055
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2024
The quantity of what the sample constitutes: 16 yd
A brief description of the sample: Approach Slab NB
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 21-0051
Structure name: Perfume Creek Bridge
The fabricator/manufacturer/facility name: Shamrock Napa
The concrete mix design number: D101C5E1
The truck number from where the sample was collected: 2436
The batch plant ticket number from where the sample was collected: 693817
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Approach Slab NB
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-09-27-70-2
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Submitted By Organization: CT D04 - Fairfield Construction Field Office 59-545
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: alejandro.lara@dot.ca.gov
Organization Phone: (510) 714-7055
Data has not been verified.
DIME Test ID: 2024-09-27-70-3
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/29/2024
Date Tested: 10/28/2024
Submitted By Organization: CT HQ - Vallejo Field Laboratory
Organization Address: 690 Walnut,
Organization City: vallejo
Organization State: CA
Organization Zipcode: 94592
Organization Email: yannick.aranas@dot.ca.gov
Organization Phone: (916) 639-4315
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Apparent mass of submerged cylinder 1
|
1 lb
|
|
Average diameter of cylinder 1
|
4.06 in
|
|
Average diameter of cylinder 2
|
4.00 in
|
|
Average diameter of cylinder 3
|
4.08 in
|
|
Cross sectional area of cylinder 1
|
12.95 in^2
|
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
|
Cross sectional area of cylinder 3
|
13.07 in^2
|
|
Compressive strength (to nearest 10 psi)
|
5070 psi
|
|
Maximum load on cylinder 1
|
65591 lb
|
|
Maximum load on cylinder 2
|
69323 lb
|
|
Maximum load on cylinder 3
|
62670 lb
|
|
Compressive strength of cylinder 1
|
4960.0 psi
|
|
Type of fracture pattern of cylinder 1
|
3
|
|
Compressive strength of cylinder 2
|
5460.0 psi
|
|
Compressive strength of cylinder 3
|
4790 psi
|
|
Type of fracture pattern of cylinder 2
|
3
|
|
Type of fracture pattern of cylinder 3
|
3
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
0.98
|
|
Correction factor for cylinder 2
|
0.99
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
31 days
|
|
Age of specimen in hours
|
no data0 hours
|
|
Serial number of delivery ticket, if available
|
no data
|