Print Report | Back to Sample Detail

Sample Record for 2024-10-14-36

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994588 DEA: 081H3904 EFIS: 0817000032 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R20.5/R21.6,R25.5/R30.7
Work Description: CONSTRUCT BUILDING, ROADWAY EXC, JPCP, AND TEMPORARY BARRIER SYSTEM.
Location Description: SAN BERNARDINO COUNTY FROM 0.6 MILE NORTH OF CLEGHORN ROAD UNDERCROSSING TO 0.5 MILE SOUTH OF ROUTE 138 AND FROM 0.5 MILE SOUTH OF TRUCK SAFETY CHECK AREA TO 0.4 MILE NORTH OF OAK HILL ROAD OVERCROSSING
Contractor Name: POWELL CONSTRUCTORS INC
Contractor Address: 8555 BANANA AVE, FONTANA, CA 92335
Resident Engineer: Mauricio Santa Cruz Structure Rep.: Oluwatayo (Tayo) Ogeyemi

Sample Information

DIME Sample ID: 2024-10-14-36
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/14/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/15/2024
The quantity of what the sample constitutes: 2 BOXES OF HMA
A brief description of the sample: 3/4" HMA A SP R15 .75% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0553A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Oro Grande

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 224112A ORO SJR
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-10-14-36-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/24/2024
Date Tested: 10/18/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2135.6 g
Corrected Asphalt Binder Content 4.72 %
Mass Loss 111.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.36 %
Moisture Content no data0 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C