Print Report | Back to Sample Detail

Sample Record for 2024-09-23-78

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993387 DEA: 07323404 EFIS: 0716000064 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-R59.5/R67.9
Work Description: PLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY INC
Contractor Address: 13170 TELEFAIR AVE, SYLMAR, CA 91342
Resident Engineer: Oscar Osorio Structure Rep.: Chanh Tong

Sample Information

DIME Sample ID: 2024-09-23-78
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 09/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/23/2024
The quantity of what the sample constitutes: 300 CY
A brief description of the sample: LCB-RS
From where was the sample collected: Job Site
Laboratory sample identification: 24-2960
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Security Paving

Material Information

The concrete mix design number: G3-19-CTSLCB-165
The truck number from where the sample was collected: 8
The batch plant ticket number from where the sample was collected: 3
Concrete batch plant: Security Paving
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Truck chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-09-23-78-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 10/13/2024
Date Tested: 09/30/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 407-6963
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 6.06 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.84 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 890 psi
Maximum load on cylinder 1 26062 lb
Maximum load on cylinder 2 24991 lb
Compressive strength of cylinder 1 903.7 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 880.9 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours