Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-10-10-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Annual Source Testing
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 10/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2024
The quantity of what the sample constitutes: 2 random samples
A brief description of the sample: # 11 Rebar Audit Samples
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coatings Ogden, UT
Rebar Heat Number(s): 1201061345
Rebar Epoxy Batch Number(s): G240769
Rebar Coating Specification: ASTM A775
Rebar Size (#): #11
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coatings
Rebar Powder Manufacturer: IFS Coatings
Release Number:
Quality Assurance Code:
DIME Test ID: 2024-10-10-4-1
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 10/25/2024
Date Tested: 10/24/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
First Bar Mean
|
10.55
|
|
Second Bar Mean
|
10.52
|
|
Lower spec. limit LSL
|
7
|
|
Upper spec. limit USL
|
16
|
|
Bar # for First Bar
|
1
|
|
Bar # for Second Bar
|
2
|
|
Total mean value
|
10.53
|
|
Total number of values less than LSL
|
no data
|
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2024-10-10-4-2
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 10/25/2024
Date Tested: 10/24/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Total Number of Holiday
|
1
|
|
Total Length
|
5
|
|
Holidays Per Linear Foot of Bar
|
0.2
|
|
Holiday Test Pass/Fail
|
Pass
|
|
Bend Test Pass/Fail
|
NA
|